{"id":2090,"date":"2026-07-19T09:00:00","date_gmt":"2026-07-19T01:00:00","guid":{"rendered":"https:\/\/lbajiele.com\/news\/315kva-dry-type-specifications-applications-guide\/"},"modified":"2026-07-19T18:40:36","modified_gmt":"2026-07-19T10:40:36","slug":"315kva-dry-type-specifications-applications-guide","status":"publish","type":"post","link":"https:\/\/lbajiele.com\/ar\/blog\/315kva-dry-type-specifications-applications-guide\/","title":{"rendered":"\u0645\u062d\u0648\u0644 \u0637\u0627\u0642\u0629 \u062c\u0627\u0641 \u0628\u0642\u0648\u0629 315 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631: \u062f\u0644\u064a\u0644 \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0648\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a"},"content":{"rendered":"<p style=\"margin:0 0 16px;line-height:1.7\">A <strong>315KVA dry type power transformer<\/strong> supports indoor commercial and light-industrial distribution where ventilation and fire planning favor resin-insulated technology.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">At 315 kVA, align voltage class, cooling, impedance, and documented losses with your single-line diagram and utility requirements before issuing an RFQ. This guide focuses on practical evaluation steps for buyers\u2014measurement, documentation, and lifecycle support\u2014not generic marketing claims.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Cross-check public catalog data on lbajiele.com and confirm project-specific limits with your utility or consulting engineer.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"315KVA transformer planning overview for industrial distribution projects\" src=\"https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/06\/80KVA-dry-typeelectrical-Transformer.3.webp\" \/><\/p>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 style=\"margin:42px 0 14px\">Contents<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#part-1-what-a-315kva-unit-does-in-your-network\">Part 1. What a 315KVA unit does in your network<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-2-key-specifications-at-315-kva\">Part 2. Key specifications at 315 kVA<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-3-loading-environment-and-compliance-notes\">Part 3. Loading, environment, and compliance notes<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-4-documentation-and-rfq-checklist\">Part 4. Documentation and RFQ checklist<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-5-commissioning-monitoring-and-long-term-operations\">Part 5. Commissioning, monitoring, and long-term operations<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-6-product-recommendation-and-fit-boundary\">Part 6. Product recommendation and Fit Boundary<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-7-common-specification-mistakes\">Part 7. Common specification mistakes<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px\" id=\"part-1-what-a-315kva-unit-does-in-your-network\">Part 1. What a 315KVA unit does in your network<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Hotels, airports, and mixed-use buildings frequently evaluate this kVA class for basement or rooftop electrical rooms. Application notes should cover enclosure IP targets and fan maintenance access.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Whether specified as power or distribution duty, nameplate kVA, tap range, and vector group are binding design inputs\u2014not marketing labels.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Buyers at this rating usually coordinate prospective fault current, downstream protection, and demand profile before finalizing transformer specifications.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Treat selection as a lifecycle decision: rated kVA, losses, and impedance should match documented site behavior after commissioning.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">For related context, see the <a href=\"https:\/\/lbajiele.com\/ar\/blog\/315kva-oil-immersed-power-transformer-reliable-distribution-solution\/\">315KVA oil immersed distribution solution<\/a>.<br \/>\nFor related context, see the <a href=\"https:\/\/lbajiele.com\/ar\/blog\/250kva-dry-type-power-specifications-guide\/\">250KVA dry type specifications guide<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px\" id=\"part-2-key-specifications-at-315-kva\">Part 2. Key specifications at 315 kVA<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Fix primary class and secondary voltage on the approved single-line diagram before comparing vendor catalogs.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Include prospective fault level and relay coordination when reviewing short-circuit impedance with your protection engineer.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">LBAJI publishes catalog reference data for <strong>10 kV SC(B)11-315 (catalog reference)<\/strong> on the <a href=\"https:\/\/lbajiele.com\/ar\/product\/scb-resin-insulation-dry-transformer-series\/\">SC(B) resin insulated dry transformer series<\/a> page. Compare <strong>no-load and load losses<\/strong> at the agreed reference temperature before normalizing bids. Treat the table below as a quotation starting point; issued drawings and type-test reports govern the final PO.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"Technical review of 315KVA transformer parameters and loss data\" src=\"https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/06\/80KVA-dry-typeelectrical-Transformer.2.webp\" \/><\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u0645\u0639\u0627\u0645\u0644<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Catalog reference (315 kVA)<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Why it matters<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Rated capacity<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">315 kVA<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Continuous duty basis<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Rated kVA and voltage combination<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">6\u201311 kV \/ 0.4 kV typical (confirm on PO)<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Protection and cable sizing<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Vector group and tap range<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Dyn11 or Yyn0; \u00b15% or \u00b12\u00d72.5% typical<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Grounding and voltage regulation<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">No-load loss<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">0.79 kW<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Lifecycle energy cost<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Load loss<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">3.73 kW at 155\u00b0C (B) reference temperature<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Thermal and efficiency planning<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">No-load current<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">1%<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Magnetizing design check<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Short-circuit impedance<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">6%<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Protection coordination<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cooling method and enclosure<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">dry type resin insulated<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Site layout and fire planning<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Overall dimensions<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">1020 \u00d7 790 \u00d7 1060 mm<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Civil and lifting planning<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Weight<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">1130 kg<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Foundation and transport<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">Confirm the exact voltage combination, vector group, and tap steps required by your interconnection agreement.<\/p>\n<h2 style=\"margin:42px 0 14px\" id=\"part-3-loading-environment-and-compliance-notes\">Part 3. Loading, environment, and compliance notes<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Loading above nameplate without documented approval can affect warranty and operating margin.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Harmonic-rich loads may require study before energization; record measured THD at the point of common coupling when drives dominate the profile.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Altitude, ambient temperature, and enclosure influence derating. State elevation, average and maximum ambient, and indoor versus outdoor installation in every RFQ.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Fire separation, spill containment, or ventilation rules depend on local codes and the selected cooling class\u2014confirm with the authority having jurisdiction before room layout freeze.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">EPC contracts should list language for nameplate markings, terminal labeling, and shipping Incoterms to avoid rework at customs. As-built photos of ratio tests simplify future audits.<\/p>\n<h2 style=\"margin:42px 0 14px\" id=\"part-4-documentation-and-rfq-checklist\">Part 4. Documentation and RFQ checklist<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Use the checklist below as an RFQ attachment. Your EPC contract or utility may require additional items.<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Document \/ item<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Purpose<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">When to request<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Factory type or routine test report<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Verify kVA, voltage, losses, impedance<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Before purchase order<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">GA drawing and foundation load<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Civil and lifting design<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Design phase<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Wiring \/ connection diagram<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Termination and grounding<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Before shipment<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Loss and impedance certificate<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Bid normalization<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tender comparison<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Spare parts list<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Bushings, gaskets, fans, sensors<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Contract negotiation<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Commissioning checklist<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ratio, polarity, grounding tests<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Before energization<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>RFQ inputs to include:<\/strong> primary and secondary voltage, vector group, tap range, altitude, ambient range, required cooling class, impedance target, delivery Incoterm, witness-test requirement, and language for nameplate markings.<\/p>\n<h2 style=\"margin:42px 0 14px\" id=\"part-5-commissioning-monitoring-and-long-term-operations\">Part 5. Commissioning, monitoring, and long-term operations<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Commissioning should verify ratio, polarity, grounding, and protective relay coordination before loading the transformer to production demand.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Functional tests typically include insulation resistance and, for liquid-filled units, oil dielectric strength under agreed procedures.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">After energization, monitor temperature, load profile, and abnormal gas or hot-spot trends according to manufacturer guidance.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Schedule post-warranty reviews when plant expansion is planned\u2014315 kVA feeders often need tap review within a few years of major load additions.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Maintain as-built single-line diagrams after feeder changes. Baseline load and temperature readings taken at commissioning simplify future troubleshooting.<\/p>\n<h2 style=\"margin:42px 0 14px\" id=\"part-6-product-recommendation-and-fit-boundary\">Part 6. Product recommendation and Fit Boundary<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Product recommendation:<\/strong> For 315 kVA class projects, start engineering review with the <a href=\"https:\/\/lbajiele.com\/ar\/product\/scb-resin-insulation-dry-transformer-series\/\">SC(B) resin insulated dry transformer series<\/a> and the broader <a href=\"https:\/\/lbajiele.com\/ar\/transformer\/\">transformer category<\/a>.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"315KVA transformer product line for RFQ and engineering review\" src=\"https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/06\/80KVA-dry-type-disctribution-Transformer.3.webp\" \/><\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Better fit<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Poor fit without extra study<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Industrial\/commercial MV-LV distribution with documented load<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Unknown harmonic profile with no mitigation plan<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Buyers who can supply SL diagram and protection data<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Rush PO without voltage class confirmation<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Projects accepting catalog-to-drawing confirmation cycle<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Assumed utility approval without interconnection review<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">Submit primary\/secondary voltage, vector group, ambient conditions, altitude, and required test documents through <a href=\"https:\/\/lbajiele.com\/ar\/contact-us\/\">\u0627\u062a\u0635\u0644 \u0628\u0646\u0627<\/a> for model-specific confirmation.<\/p>\n<h2 style=\"margin:42px 0 14px\" id=\"part-7-common-specification-mistakes\">Part 7. Common specification mistakes<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">Comparing quotations that use different impedance bases or reference temperatures for losses.<\/li>\n<li style=\"margin:0 0 8px\">Using catalog weight for foundation design without the issued GA drawing.<\/li>\n<li style=\"margin:0 0 8px\">Ignoring altitude or ambient derating on outdoor installations.<\/li>\n<li style=\"margin:0 0 8px\">Selecting vector group without confirming grounding philosophy.<\/li>\n<li style=\"margin:0 0 8px\">Treating marketing brochures as substitutes for type-test or routine-test reports.<\/li>\n<li style=\"margin:0 0 8px\">Mixing 315 kVA nameplate with downstream panel ratings that assume a different secondary voltage.<\/li>\n<\/ul>\n<h2 style=\"margin:42px 0 14px\">\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h2>\n<h3 style=\"margin:28px 0 12px\">What is a 315KVA transformer used for?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">It typically steps medium voltage to low-voltage distribution for industrial campuses, utility secondary networks, and large commercial plants at the 315 kVA rating.<\/p>\n<h3 style=\"margin:28px 0 12px\">What cooling is typical at 315 kVA?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Dry-type units rely on natural air (AN) with optional forced-air cooling for overload strategies\u2014confirm enclosure and ventilation on the datasheet.<\/p>\n<h3 style=\"margin:28px 0 12px\">What primary voltages are common?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Public LBAJI catalogs list 6\u201311 kV class primaries for many distribution units; confirm with your single-line diagram and utility rules.<\/p>\n<h3 style=\"margin:28px 0 12px\">What impedance should I expect?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Catalog reference for 315 kVA is about 6%; verify with your protection study before final approval.<\/p>\n<h3 style=\"margin:28px 0 12px\">What documents should I request?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Type or routine test reports, GA drawings, wiring diagrams, loss certificates, tap data, and spare-parts lists.<\/p>\n<h3 style=\"margin:28px 0 12px\">Can this rating be used outdoors?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Indoor ventilated electrical rooms are typical; outdoor dry-type requires purpose-built enclosures\u2014confirm IP rating and HVAC on drawings.<\/p>\n<h3 style=\"margin:28px 0 12px\">How do I compare dry type vs oil at this size?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Compare fire risk, maintenance, ventilation or oil containment, lifecycle losses, and indoor\/outdoor constraints\u2014not headline kVA alone.<\/p>\n<h2 style=\"margin:42px 0 14px\">References<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/webstore.iec.ch\/publication\/5998\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60076-1: Power transformers \u2014 General<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/standards.ieee.org\/standard\/C57.12.00-2015.html\" rel=\"nofollow noopener\" target=\"_blank\">IEEE C57.12.00: Standard for General Requirements for Liquid-Immersed Distribution Transformers<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/standards.ieee.org\/standard\/C57.12.91-2011.html\" rel=\"nofollow noopener\" target=\"_blank\">IEEE C57.12.91: Standard for Dry-Type Distribution Transformers<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/low-voltage-power-distribution-controls-systems\/transformer\/transformer-dry-type-install-best-practices-white-paper-WP009003EN.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Eaton dry-type installation best practices (white paper)<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>A 315KVA dry type power transformer supports indoor commercial and light-industrial distribution where ventilation and fire planning favor resin-insulated technology. At 315 kVA, align voltage class, cooling, impedance, and documented losses with your single-line diagram and utility requirements before issuing an RFQ. This guide focuses on practical evaluation steps for buyers\u2014measurement, documentation, and lifecycle support\u2014not [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":1944,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[31],"tags":[],"class_list":["post-2090","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/lbajiele.com\/ar\/wp-json\/wp\/v2\/posts\/2090","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lbajiele.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/lbajiele.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/lbajiele.com\/ar\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/lbajiele.com\/ar\/wp-json\/wp\/v2\/comments?post=2090"}],"version-history":[{"count":1,"href":"https:\/\/lbajiele.com\/ar\/wp-json\/wp\/v2\/posts\/2090\/revisions"}],"predecessor-version":[{"id":2098,"href":"https:\/\/lbajiele.com\/ar\/wp-json\/wp\/v2\/posts\/2090\/revisions\/2098"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lbajiele.com\/ar\/wp-json\/wp\/v2\/media\/1944"}],"wp:attachment":[{"href":"https:\/\/lbajiele.com\/ar\/wp-json\/wp\/v2\/media?parent=2090"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/lbajiele.com\/ar\/wp-json\/wp\/v2\/categories?post=2090"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/lbajiele.com\/ar\/wp-json\/wp\/v2\/tags?post=2090"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}