{"id":2131,"date":"2026-07-31T09:00:00","date_gmt":"2026-07-31T01:00:00","guid":{"rendered":"https:\/\/lbajiele.com\/?p=2131"},"modified":"2026-07-21T11:38:59","modified_gmt":"2026-07-21T03:38:59","slug":"pad-mounted-vs-substation-transformer-selection-guide-utilities","status":"publish","type":"post","link":"https:\/\/lbajiele.com\/ar\/blog\/pad-mounted-vs-substation-transformer-selection-guide-utilities\/","title":{"rendered":"\u0645\u062d\u0648\u0644 \u0645\u062b\u0628\u062a \u0639\u0644\u0649 \u0627\u0644\u0648\u0633\u0627\u062f\u0629 \u0645\u0642\u0627\u0628\u0644 \u0645\u062d\u0648\u0644 \u0645\u062d\u0637\u0629 \u0641\u0631\u0639\u064a\u0629: \u062f\u0644\u064a\u0644 \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0644\u0644\u0645\u0631\u0627\u0641\u0642 \u0627\u0644\u062e\u062f\u0645\u064a\u0629"},"content":{"rendered":"<div class=\"b2b-article\">\n<p style=\"margin:0 0 16px;line-height:1.7\">\u0627\u0644 <strong>pad-mounted vs substation transformer<\/strong> decision is really a siting decision: public space with incidental contact, or a controlled yard behind a fence.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Utilities and EPC teams choose between tamper-resistant enclosed units and open substation designs based on access, protection philosophy, and maintenance practice. This guide compares them factor by factor.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Confirm network practice and site ownership before shortlisting either design.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"Pad-mounted and substation transformer siting comparison overview\" src=\"https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/Power-Transformation-Station.webp\" \/><\/figure>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\">\u0627\u0644\u0645\u062d\u062a\u0648\u064a\u0627\u062a<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#part-1-two-designs-for-two-siting-realities\">Part 1. Two designs for two siting realities<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-2-comparison-at-a-glance\">Part 2. Comparison at a glance<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-3-enclosure-security-and-public-access\">Part 3. Enclosure, security, and public access<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-4-protection-and-switching-differences\">Part 4. Protection and switching differences<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-5-installation-and-lifecycle\">Part 5. Installation and lifecycle<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-6-product-recommendation-and-fit-boundary\">\u0627\u0644\u062c\u0632\u0621 \u0627\u0644\u0633\u0627\u062f\u0633: \u062a\u0648\u0635\u064a\u0627\u062a \u0627\u0644\u0645\u0646\u062a\u062c\u0627\u062a \u0648\u062d\u062f\u0648\u062f \u0627\u0644\u0645\u0644\u0627\u0621\u0645\u0629<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-7-common-selection-mistakes\">Part 7. Common selection mistakes<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#faq\">\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#references\">\u0627\u0644\u0645\u0631\u0627\u062c\u0639<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-1-two-designs-for-two-siting-realities\">Part 1. Two designs for two siting realities<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">A pad-mounted transformer lives in public space: locked, dead-front, tamper-resistant, on a ground-level pad among buildings.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">A substation transformer lives in a controlled compound: open bushings, external protection, room to maintain, behind fencing and signage.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u0644\u0644\u0645\u0632\u064a\u062f \u0645\u0646 \u0627\u0644\u0633\u064a\u0627\u0642\u060c \u0627\u0646\u0638\u0631 <a href=\"https:\/\/lbajiele.com\/ar\/blog\/understanding-distribution-transformers-types-and-applications\/\">distribution transformer types and applications overview<\/a>.<br \/>\n\u0644\u0644\u0645\u0632\u064a\u062f \u0645\u0646 \u0627\u0644\u0633\u064a\u0627\u0642\u060c \u0627\u0646\u0638\u0631 <a href=\"https:\/\/lbajiele.com\/ar\/blog\/dry-type-vs-oil-immersed-transformer-distribution-comparison-guide\/\">\u062f\u0644\u064a\u0644 \u0645\u0642\u0627\u0631\u0646\u0629 \u0628\u064a\u0646 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062c\u0627\u0641\u0629 \u0648\u0627\u0644\u0645\u063a\u0645\u0648\u0631\u0629 \u0628\u0627\u0644\u0632\u064a\u062a<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-2-comparison-at-a-glance\">Part 2. Comparison at a glance<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Use the matrix in early siting reviews, then confirm details on issued drawings.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"Enclosure and protection comparison for pad-mounted and substation designs\" src=\"https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/High-and-low-voltage-preinstalled-substation.webp\" \/><\/figure>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u0639\u0627\u0645\u0644<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Pad-mounted<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Substation type<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Typical siting<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Public and commercial areas, ground-level pad<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Fenced utility or plant compound<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u0633\u064a\u0627\u062c<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Sealed, lockable, dead-front cabinet<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Open terminals with separate switchgear<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Public safety approach<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tamper-resistant enclosure itself<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Perimeter security and clearance distances<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Protection and switching<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Internal fusing or integrated switching per design<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">External relays, breakers, and disconnects<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Capacity range<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Distribution ratings<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Distribution through large power ratings<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Maintenance access<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Front compartments, limited internal access<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Full walk-around access to every fitting<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">IEEE C57.12.34 covers pad-mounted compartmental designs, while substation practice follows general power transformer standards\u2014use both to anchor RFQ language.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-3-enclosure-security-and-public-access\">Part 3. Enclosure, security, and public access<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Pad-mounted cabinets integrate cable terminations behind locked, dead-front panels precisely because the public can touch the enclosure.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Substation designs assume trained access only, trading enclosure cost for maintainability and heat dissipation.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Vandalism exposure, flood level, and vehicle impact risk all belong in the siting review.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-4-protection-and-switching-differences\">Part 4. Protection and switching differences<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Pad-mounted designs often carry integrated fusing and load-break switching sized for the radial or loop network they serve.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Substation transformers rely on external protection\u2014relays and breakers\u2014that a utility can coordinate and expand over time.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Network philosophy usually decides: loop-fed public distribution favors pad-mounted units, while stations with evolving protection favor substation designs.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-5-installation-and-lifecycle\">Part 5. Installation and lifecycle<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Pad installation needs a compact civil pad, cable trenches, and clear working space at the front doors.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">A substation unit needs a compound: foundations, containment where oil rules apply, fencing, and clearance distances.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Lifecycle differs too\u2014compartment access limits some diagnostics on pad-mounted units, while substation yards accept full test crews.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-6-product-recommendation-and-fit-boundary\">\u0627\u0644\u062c\u0632\u0621 \u0627\u0644\u0633\u0627\u062f\u0633: \u062a\u0648\u0635\u064a\u0627\u062a \u0627\u0644\u0645\u0646\u062a\u062c\u0627\u062a \u0648\u062d\u062f\u0648\u062f \u0627\u0644\u0645\u0644\u0627\u0621\u0645\u0629<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>\u062a\u0648\u0635\u064a\u0629 \u0627\u0644\u0645\u0646\u062a\u062c:<\/strong> Both paths start from distribution series selection; enclosure and protection integration come next. Start at the <a href=\"https:\/\/lbajiele.com\/ar\/transformer\/\">\u0641\u0626\u0629 \u0645\u0646\u062a\u062c\u0627\u062a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a<\/a>, \u060c \u062b\u0645 \u0631\u0627\u062c\u0639 <a href=\"https:\/\/lbajiele.com\/ar\/product\/s-m-oil-immersed-power-transformer\/\">\u0633\u0644\u0633\u0644\u0629 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0645\u063a\u0645\u0648\u0631\u0629 \u0628\u0627\u0644\u0632\u064a\u062a S\u25a1-M<\/a> \u0648 <a href=\"https:\/\/lbajiele.com\/ar\/product\/scb-resin-insulation-dry-transformer-series\/\">\u0633\u0644\u0633\u0644\u0629 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062c\u0627\u0641 \u0627\u0644\u0645\u0639\u0632\u0648\u0644\u0629 \u0628\u0627\u0644\u0631\u0627\u062a\u0646\u062c SC(B)<\/a> \u062e\u0644\u0627\u0641\u0627\u064b \u0644\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0645\u0639\u062a\u0645\u062f\u0629.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"Distribution transformer series for utility selection\" src=\"https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/03\/1.OIL-IMMERSED-POWER-TRANSFORMER.webp\" \/><\/figure>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u0645\u0644\u0627\u0626\u0645\u0629 \u0623\u0641\u0636\u0644<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u0645\u0646\u0627\u0633\u0628\u0629 \u0636\u0639\u064a\u0641\u0629 \u0628\u062f\u0648\u0646 \u062f\u0631\u0627\u0633\u0629 \u0625\u0636\u0627\u0641\u064a\u0629<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Utilities standardizing loop-fed public distribution<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Public siting for open-terminal substation designs<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Plants with fenced compounds and protection crews<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Pad-mounted units where full test access is routine<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Projects matching enclosure to flood and impact risk<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Choosing by first cost without a siting review<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u0642\u062f\u0651\u0645 \u0642\u062f\u0631\u0629 \u0627\u0644\u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631 (kVA) \u0648\u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u062c\u0647\u062f\u060c \u0648\u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u062a\u062c\u0647\u0627\u062a \u0648\u0646\u0637\u0627\u0642 \u0627\u0644\u0635\u0646\u0627\u0628\u064a\u0631\u060c \u0648\u0627\u0644\u0644\u0627\u062d\u0645\u0644 (\u0644\u0627 \u0634\u064a\u0621) \u0648\u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062d\u0645\u0644\u060c \u0648\u0637\u0631\u064a\u0642\u0629 \u0627\u0644\u062a\u0628\u0631\u064a\u062f \u0648\u0627\u0644\u063a\u0644\u0627\u0641\u060c \u0648\u0647\u062f\u0641 \u0645\u0639\u0627\u0648\u0642\u0629 \u0642\u0635\u0631 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0645\u0646 \u062e\u0644\u0627\u0644 <a href=\"https:\/\/lbajiele.com\/ar\/contact-us\/\">\u0627\u062a\u0635\u0644 \u0628\u0646\u0627<\/a> \u0644\u0644\u062a\u0623\u0643\u064a\u062f \u0627\u0644\u062e\u0627\u0635 \u0628\u0627\u0644\u0646\u0645\u0648\u0630\u062c.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-7-common-selection-mistakes\">Part 7. Common selection mistakes<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">Siting open substation designs in publicly accessible areas.<\/li>\n<li style=\"margin:0 0 8px\">Buying pad-mounted units where maintenance practice expects walk-around access.<\/li>\n<li style=\"margin:0 0 8px\">Ignoring flood level for ground-level pad enclosures.<\/li>\n<li style=\"margin:0 0 8px\">Underestimating compound civil costs when comparing prices.<\/li>\n<li style=\"margin:0 0 8px\">Leaving protection philosophy undefined until after purchase.<\/li>\n<li style=\"margin:0 0 8px\">Skipping the network standards review before fixing the design type.<\/li>\n<\/ul>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"faq\">\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h2>\n<h3 style=\"margin:28px 0 12px\">What is a pad-mounted transformer?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">A distribution transformer in a locked, tamper-resistant, dead-front enclosure installed on a ground-level pad in areas with public access.<\/p>\n<h3 style=\"margin:28px 0 12px\">How does a substation transformer differ from a pad-mounted unit?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">It uses open terminals with external protection inside a controlled compound, offering full maintenance access and larger ratings.<\/p>\n<h3 style=\"margin:28px 0 12px\">Which option suits urban residential feeders?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Pad-mounted designs\u2014enclosure safety and compact pads fit public streetscapes and loop-fed networks.<\/p>\n<h3 style=\"margin:28px 0 12px\">Do pad-mounted transformers need fencing?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Generally the enclosure itself provides the public-safety barrier; local rules may still add spacing or bollards.<\/p>\n<h3 style=\"margin:28px 0 12px\">Which option is easier to maintain?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Substation designs\u2014open access suits full diagnostics; pad-mounted compartments limit some field work by design.<\/p>\n<h3 style=\"margin:28px 0 12px\">Can pad-mounted transformers serve industrial loads?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Yes within distribution ratings\u2014many plants use them for outlying loads; large or expandable stations favor substation designs.<\/p>\n<h3 style=\"margin:28px 0 12px\">What data should utilities send with an RFQ?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Network type, fault levels, enclosure and security requirements, flood and impact exposure, and the protection philosophy.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"references\">\u0627\u0644\u0645\u0631\u0627\u062c\u0639<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/standards.ieee.org\/ieee\/C57.12.34\/7180\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE C57.12.34: Requirements for pad-mounted compartmental-type transformers<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/standards.ieee.org\/ieee\/C57.12.10\/5117\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE C57.12.10: Requirements for substation transformers<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/588\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60076-1: \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0642\u062f\u0631\u0629 - \u0627\u0644\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0639\u0627\u0645\u0629<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>The pad-mounted vs substation transformer decision is really a siting decision: public space with incidental contact, or a controlled yard behind a fence. Utilities and EPC teams choose between tamper-resistant enclosed units and open substation designs based on access, protection philosophy, and maintenance practice. This guide compares them factor by factor. Confirm network practice and [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":1554,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[31],"tags":[],"class_list":["post-2131","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/lbajiele.com\/ar\/wp-json\/wp\/v2\/posts\/2131","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lbajiele.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/lbajiele.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/lbajiele.com\/ar\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/lbajiele.com\/ar\/wp-json\/wp\/v2\/comments?post=2131"}],"version-history":[{"count":1,"href":"https:\/\/lbajiele.com\/ar\/wp-json\/wp\/v2\/posts\/2131\/revisions"}],"predecessor-version":[{"id":2144,"href":"https:\/\/lbajiele.com\/ar\/wp-json\/wp\/v2\/posts\/2131\/revisions\/2144"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lbajiele.com\/ar\/wp-json\/wp\/v2\/media\/1554"}],"wp:attachment":[{"href":"https:\/\/lbajiele.com\/ar\/wp-json\/wp\/v2\/media?parent=2131"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/lbajiele.com\/ar\/wp-json\/wp\/v2\/categories?post=2131"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/lbajiele.com\/ar\/wp-json\/wp\/v2\/tags?post=2131"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}