{"id":1263,"date":"2026-04-07T13:57:36","date_gmt":"2026-04-07T05:57:36","guid":{"rendered":"https:\/\/wvefouvvpp.wpdns.site\/?post_type=product&#038;p=1263"},"modified":"2026-08-26T09:54:34","modified_gmt":"2026-08-26T09:54:34","slug":"kyn28a-12-metal-clad-withdrawable-ac-switchgear","status":"publish","type":"product","link":"https:\/\/lbajiele.com\/de\/produkt\/kyn28a-12-metal-clad-withdrawable-ac-switchgear\/","title":{"rendered":"KYN28A-12 Metal-clad Withdrawable AC Switchgear"},"content":{"rendered":"<h2>Technical Parameters<\/h2>\n<table style=\"border-collapse: collapse; width: 630.77pt;\" border=\"0\" width=\"841\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 13.50pt; width: 339.00pt;\" colspan=\"2\" width=\"452\" height=\"18\">Artikel<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">Unit<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">Data<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 13.50pt; width: 339.00pt;\" colspan=\"2\" width=\"452\" height=\"18\">Rated Voltage<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">kV<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">6\u30017.2\u300112<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 13.50pt; width: 339.00pt;\" colspan=\"2\" width=\"452\" height=\"18\">Rated Frequency<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">Hz<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">50<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 13.50pt; width: 339.00pt;\" colspan=\"2\" width=\"452\" height=\"18\">Rated Current Of Circuit Breaker<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">A<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">630\u30011250\u30011600\u30012000\u30012500\u30013150<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 13.50pt; width: 339.00pt;\" colspan=\"2\" width=\"452\" height=\"18\">Rated Current Of Switchgear<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">A<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">630\u30011250\u30011600\u30012000\u30012500\u30013150<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 13.50pt; width: 339.00pt;\" colspan=\"2\" width=\"452\" height=\"18\">Rated Short-Time Withstand Current<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">kA<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">20\u300125\u300131.5\u300140<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 13.50pt; width: 339.00pt;\" colspan=\"2\" width=\"452\" height=\"18\">Rated Peak Withstand Current<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">kA<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">50\u300163\u300180\u3001100<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 13.50pt; width: 339.00pt;\" colspan=\"2\" width=\"452\" height=\"18\">Rated Short-Circuit Breaking Current<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">kA<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">20\u300125\u300131.5\u300140<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 13.50pt; width: 339.00pt;\" colspan=\"2\" width=\"452\" height=\"18\">Rated Short-Circuit Making Current<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">kA<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">50\u300163\u300180\u3001100<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 27.00pt; width: 158.25pt;\" rowspan=\"2\" width=\"211\" height=\"36\">Rated Insulation Level<br \/>\n1-Minute Power-Frequency<br \/>\nWithstand Voltage<\/td>\n<td class=\"et2\" style=\"width: 180.75pt;\" width=\"241\">Between poles\u3001Pole-to-earth<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">kV<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">24\u300132\u300142<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"width: 180.75pt;\" width=\"241\">Across the open contacts<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">kV<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">24\u300132\u300142<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 27.00pt; width: 158.25pt;\" rowspan=\"2\" width=\"211\" height=\"36\">Lightning Impulse<br \/>\nWithstand Voltage<br \/>\n(Peak)<\/td>\n<td class=\"et2\" style=\"width: 180.75pt;\" width=\"241\">Between poles\u3001Pole-to-earth<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">kV<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">40\u300160\u300175<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"width: 180.75pt;\" width=\"241\">Across the open contacts<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">kV<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">46\u300170\u300185<\/td>\n<\/tr>\n<tr style=\"height: 67.50pt;\">\n<td class=\"et2\" style=\"height: 67.50pt; width: 397.50pt;\" colspan=\"3\" width=\"530\" height=\"90\">Degree of Protection<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">The shell is IP4X, and when the compartment and circuit breaker room doors are opened, it is IP2X<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>The KYN28A-12(Z) indoor AC metal-clad withdrawable switchgear is designed for three-phase, 50 Hz AC power distribution systems and is used for the reception and distribution of electrical energy, as well as the control, protection, and monitoring of electrical circuits.<\/p>","protected":false},"featured_media":1264,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[27],"product_tag":[],"class_list":["post-1263","product","type-product","status-publish","has-post-thumbnail","product_cat-medium-voltage-switchgear","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/lbajiele.com\/de\/wp-json\/wp\/v2\/product\/1263","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lbajiele.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/lbajiele.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/lbajiele.com\/de\/wp-json\/wp\/v2\/comments?post=1263"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lbajiele.com\/de\/wp-json\/wp\/v2\/media\/1264"}],"wp:attachment":[{"href":"https:\/\/lbajiele.com\/de\/wp-json\/wp\/v2\/media?parent=1263"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/lbajiele.com\/de\/wp-json\/wp\/v2\/product_brand?post=1263"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/lbajiele.com\/de\/wp-json\/wp\/v2\/product_cat?post=1263"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/lbajiele.com\/de\/wp-json\/wp\/v2\/product_tag?post=1263"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}