{"id":1186,"date":"2026-04-06T13:25:51","date_gmt":"2026-04-06T05:25:51","guid":{"rendered":"https:\/\/wvefouvvpp.wpdns.site\/?post_type=product&#038;p=1186"},"modified":"2026-10-16T02:55:52","modified_gmt":"2026-10-16T02:55:52","slug":"sfz11-35kv-loaded-oil-immersed-power-transformer","status":"publish","type":"product","link":"https:\/\/lbajiele.com\/es\/product\/sfz11-35kv-loaded-oil-immersed-power-transformer\/","title":{"rendered":"Transformador de potencia sumergido en aceite con carga SFZ11-35kV"},"content":{"rendered":"<h2><strong><b>Significado del modelo<\/b><\/strong><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1188\" src=\"https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/3.webp\" alt=\"\" width=\"1200\" height=\"186\" srcset=\"https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/3.webp 1200w, https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/3-300x47.webp 300w, https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/3-1024x159.webp 1024w, https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/3-768x119.webp 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/p>\n<h2><strong><b>\u00c1mbito de aplicaci\u00f3n<\/b><\/strong><\/h2>\n<p>El transformador sumergido en aceite SFZ11-1600-31500\/35 es adecuado para sistemas de energ\u00eda de CA de 50 Hz y voltaje de trabajo nominal de 35 kV, como equipo de transformaci\u00f3n para subestaciones peque\u00f1as y medianas.<\/p>\n<h2><strong><b>N\u00facleo de hierro<\/b><\/strong><\/h2>\n<p>El n\u00facleo es una chapa de acero al silicio laminado en fr\u00edo con orientaci\u00f3n magn\u00e9tica de alta permeabilidad. El n\u00facleo de hierro es un n\u00facleo de hierro convencional, un n\u00facleo de hierro de tipo apilado con juntas totalmente oblicuas, la columna del n\u00facleo de hierro es de secci\u00f3n transversal circular de m\u00faltiples pasos, y el yugo de hierro y el n\u00facleo de hierro tienen la misma secci\u00f3n transversal.<\/p>\n<h2><strong><b>Devanado<\/b><\/strong><\/h2>\n<p>Los devanados son bobinas conc\u00e9ntricas; el devanado de alta tensi\u00f3n tiene una toma requerida para la tensi\u00f3n de derivaci\u00f3n, la cual se conduce al cambiador de tomas. El conmutador est\u00e1 instalado en la tapa de la caja, y la tensi\u00f3n de derivaci\u00f3n solo se puede cambiar despu\u00e9s de cortar la fuente de alimentaci\u00f3n.<\/p>\n<h2><strong><b>Dispositivo de protecci\u00f3n de seguridad<\/b><\/strong><\/h2>\n<p>El transformador est\u00e1 equipado con un rel\u00e9 de gas y una v\u00e1lvula de alivio de presi\u00f3n.<\/p>\n<h2><strong><b>Dispositivo de protecci\u00f3n de aceite<\/b><\/strong><\/h2>\n<p>Los transformadores est\u00e1n equipados con conservadores de aceite, y un extremo est\u00e1 equipado con un indicador de nivel de aceite;<\/p>\n<p>Se debe instalar un absorbedor de humedad con sello de aceite en el conservador de aceite del transformador;<\/p>\n<h2><strong><b>Dispositivo de medici\u00f3n de temperatura de aceite<\/b><\/strong><\/h2>\n<p>Los transformadores est\u00e1n equipados con un soporte de tubo de term\u00f3metro de vidrio. El soporte del tubo est\u00e1 ubicado en la parte superior del tanque de aceite y se extiende hacia el aceite en 120\u00b110 m;<\/p>\n<p>Los transformadores de 10000 kVA y superiores est\u00e1n equipados con term\u00f3metros de se\u00f1al para exteriores;<\/p>\n<h2><strong><b>Tanque de aceite de transformador y sus accesorios<\/b><\/strong><\/h2>\n<p>El transformador generalmente no se suministra con el autom\u00f3vil, y la posici\u00f3n de soldadura del soporte inferior debe cumplir con las disposiciones de la norma GB 6451;<\/p>\n<p>La pared inferior del tanque de aceite est\u00e1 equipada con una v\u00e1lvula de muestra de aceite, y la parte inferior del tanque de aceite del transformador est\u00e1 equipada con una v\u00e1lvula de descarga de aceite lo suficientemente grande.<\/p>\n<h2><strong><b>Condiciones de trabajo<\/b><\/strong><\/h2>\n<p>Altura de instalaci\u00f3n: altitud no superior a 1000 m<\/p>\n<p>Temperatura ambiente: -40\u2103 ~ +40\u2103<\/p>\n<h2><strong><b>Transformador de potencia sumergido en aceite cargado<\/b><\/strong><\/h2>\n<table width=\"726\">\n<tbody>\n<tr>\n<td rowspan=\"2\" width=\"80\">modelo<\/td>\n<td rowspan=\"2\" width=\"50\">Calificado<br \/>\nCapacidad<br \/>\n(KVA)<\/td>\n<td colspan=\"2\" width=\"156\">Tensi\u00f3n nominal (kV)<\/td>\n<td rowspan=\"2\" width=\"65\">conexi\u00f3n<br \/>\ngrupos<\/td>\n<td colspan=\"2\" width=\"76\">P\u00e9rdida(kW)<\/td>\n<td rowspan=\"2\" width=\"48\">sin carga<br \/>\nactual<br \/>\n(%)<\/td>\n<td rowspan=\"2\" width=\"66\">impedancia<br \/>\nvoltaje<br \/>\n(%)<\/td>\n<td colspan=\"4\" width=\"185\">peso (kg)<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">alta presi\u00f3n<br \/>\n(kV)<\/td>\n<td width=\"76\">baja presi\u00f3n<br \/>\n(kV)<\/td>\n<td width=\"35\">no<br \/>\ncarga<\/td>\n<td width=\"41\">carga<\/td>\n<td width=\"42\">aceite<br \/>\npeso<\/td>\n<td width=\"42\">total<br \/>\npeso<\/td>\n<td width=\"44\">A\u00f1ade aceite<br \/>\npeso<\/td>\n<td width=\"57\">Transporte<br \/>\npeso<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-1600\/35<\/td>\n<td width=\"50\">1600<\/td>\n<td rowspan=\"7\" width=\"80\">35\u00b1<br \/>\n3\u00d72.5%<br \/>\n38.5\u00b1<br \/>\n3\u00d72.5%<\/td>\n<td rowspan=\"7\" width=\"76\">11<br \/>\n10.5<br \/>\n6.6<br \/>\n6.3<\/td>\n<td rowspan=\"7\" width=\"65\">Ynd11<\/td>\n<td width=\"35\">2.2<\/td>\n<td width=\"41\">16.2<\/td>\n<td width=\"48\">0.9<\/td>\n<td width=\"66\">6.5<\/td>\n<td width=\"42\">1.8<\/td>\n<td width=\"42\">6.24<\/td>\n<td width=\"44\">0.45<\/td>\n<td width=\"57\">4.89<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-2000\/35<\/td>\n<td width=\"50\">2000<\/td>\n<td width=\"35\">2.9<\/td>\n<td width=\"41\">18.7<\/td>\n<td width=\"48\">0.9<\/td>\n<td width=\"66\">6.5<\/td>\n<td width=\"42\">2.04<\/td>\n<td width=\"42\">7.04<\/td>\n<td width=\"44\">0.56<\/td>\n<td width=\"57\">6.24<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-2500\/35<\/td>\n<td width=\"50\">2500<\/td>\n<td width=\"35\">3.4<\/td>\n<td width=\"41\">21.7<\/td>\n<td width=\"48\">0.9<\/td>\n<td width=\"66\">6.5<\/td>\n<td width=\"42\">2.2<\/td>\n<td width=\"42\">8.1<\/td>\n<td width=\"44\">0.63<\/td>\n<td width=\"57\">7.1<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-3150\/35<\/td>\n<td width=\"50\">3150<\/td>\n<td width=\"35\">4<\/td>\n<td width=\"41\">26<\/td>\n<td width=\"48\">0.81<\/td>\n<td width=\"66\">7<\/td>\n<td width=\"42\">2.475<\/td>\n<td width=\"42\">9.3<\/td>\n<td width=\"44\">0.72<\/td>\n<td width=\"57\">713<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-4000\/35<\/td>\n<td width=\"50\">4000<\/td>\n<td width=\"35\">4.8<\/td>\n<td width=\"41\">30.6<\/td>\n<td width=\"48\">0.81<\/td>\n<td width=\"66\">7<\/td>\n<td width=\"42\">2.71<\/td>\n<td width=\"42\">11.4<\/td>\n<td width=\"44\">0.78<\/td>\n<td width=\"57\">8.1<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-5000\/35<\/td>\n<td width=\"50\">5000<\/td>\n<td width=\"35\">5.8<\/td>\n<td width=\"41\">36<\/td>\n<td width=\"48\">0.76<\/td>\n<td width=\"66\">7<\/td>\n<td width=\"42\">3.1<\/td>\n<td width=\"42\">12.9<\/td>\n<td width=\"44\">0.85<\/td>\n<td width=\"57\">9.1<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-6300\/35<\/td>\n<td width=\"50\">6300<\/td>\n<td width=\"35\">7<\/td>\n<td width=\"41\">38.7<\/td>\n<td width=\"48\">0.76<\/td>\n<td width=\"66\">7.5<\/td>\n<td width=\"42\">3.6<\/td>\n<td width=\"42\">15.4<\/td>\n<td width=\"44\">0.86<\/td>\n<td width=\"57\">12.1<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-8000\/35<\/td>\n<td width=\"50\">8000<\/td>\n<td rowspan=\"7\" width=\"80\">35\u00b1<br \/>\n3\u00d72.5%<br \/>\n38.5\u00b1<br \/>\n3\u00d72.5%<\/td>\n<td rowspan=\"7\" width=\"76\">10.5<br \/>\n6.3<\/td>\n<td rowspan=\"7\" width=\"65\">Yd11<\/td>\n<td width=\"35\">9.8<\/td>\n<td width=\"41\">42.6<\/td>\n<td width=\"48\">0.66<\/td>\n<td width=\"66\">7.5<\/td>\n<td width=\"42\">4.5<\/td>\n<td width=\"42\">17.8<\/td>\n<td width=\"44\">0.9<\/td>\n<td width=\"57\">15.4<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-10000\/35<\/td>\n<td width=\"50\">10000<\/td>\n<td width=\"35\">11.6<\/td>\n<td width=\"41\">50.5<\/td>\n<td width=\"48\">0.63<\/td>\n<td width=\"66\">7.5<\/td>\n<td width=\"42\">4.6<\/td>\n<td width=\"42\">19.3<\/td>\n<td width=\"44\">1<\/td>\n<td width=\"57\">17.2<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-12500\/35<\/td>\n<td width=\"50\">12500<\/td>\n<td width=\"35\">12.8<\/td>\n<td width=\"41\">59.9<\/td>\n<td width=\"48\">0.63<\/td>\n<td width=\"66\">8<\/td>\n<td width=\"42\">5.9<\/td>\n<td width=\"42\">24.7<\/td>\n<td width=\"44\">1.2<\/td>\n<td width=\"57\">18.7<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-16000\/35<\/td>\n<td width=\"50\">16000<\/td>\n<td width=\"35\">13.8<\/td>\n<td width=\"41\">68<\/td>\n<td width=\"48\">0.8<\/td>\n<td width=\"66\">8<\/td>\n<td width=\"42\">7.9<\/td>\n<td width=\"42\">32.5<\/td>\n<td width=\"44\">2<\/td>\n<td width=\"57\">27.1<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-20000\/35<\/td>\n<td width=\"50\">20000<\/td>\n<td width=\"35\">17.8<\/td>\n<td width=\"41\">84.6<\/td>\n<td width=\"48\">0.72<\/td>\n<td width=\"66\">8<\/td>\n<td width=\"42\">78.9<\/td>\n<td width=\"42\">36.7<\/td>\n<td width=\"44\">2.1<\/td>\n<td width=\"57\">30.9<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-25000\/35<\/td>\n<td width=\"50\">25000<\/td>\n<td width=\"35\">18.6<\/td>\n<td width=\"41\">99.6<\/td>\n<td width=\"48\">0.72<\/td>\n<td width=\"66\">8<\/td>\n<td width=\"42\">8.1<\/td>\n<td width=\"42\">40.3<\/td>\n<td width=\"44\">2.2<\/td>\n<td width=\"57\">35.4<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-31500\/35<\/td>\n<td width=\"50\">31500<\/td>\n<td width=\"35\">20.4<\/td>\n<td width=\"41\">123.8<\/td>\n<td width=\"48\">0.64<\/td>\n<td width=\"66\">10<\/td>\n<td width=\"42\">8.2<\/td>\n<td width=\"42\">42.3<\/td>\n<td width=\"44\">2.3<\/td>\n<td width=\"57\">36.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Nota: Las dimensiones y el peso proporcionados son solo de referencia para el dise\u00f1o y la selecci\u00f3n, y las dimensiones y el peso finales est\u00e1n sujetos a los planos de producto de nuestra empresa.<\/p>","protected":false},"excerpt":{"rendered":"<p>El transformador sumergido en aceite SFZ11-1600-31500\/35 es adecuado para sistemas de energ\u00eda de CA de 50 Hz y voltaje de trabajo nominal de 35 kV, como equipo de transformaci\u00f3n para subestaciones peque\u00f1as y medianas.<\/p>","protected":false},"featured_media":1187,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[102,25],"product_tag":[],"class_list":["post-1186","product","type-product","status-publish","has-post-thumbnail","product_cat-power-transformer","product_cat-transformers","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/lbajiele.com\/es\/wp-json\/wp\/v2\/product\/1186","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lbajiele.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/lbajiele.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/lbajiele.com\/es\/wp-json\/wp\/v2\/comments?post=1186"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lbajiele.com\/es\/wp-json\/wp\/v2\/media\/1187"}],"wp:attachment":[{"href":"https:\/\/lbajiele.com\/es\/wp-json\/wp\/v2\/media?parent=1186"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/lbajiele.com\/es\/wp-json\/wp\/v2\/product_brand?post=1186"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/lbajiele.com\/es\/wp-json\/wp\/v2\/product_cat?post=1186"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/lbajiele.com\/es\/wp-json\/wp\/v2\/product_tag?post=1186"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}