{"id":1186,"date":"2026-04-06T13:25:51","date_gmt":"2026-04-06T05:25:51","guid":{"rendered":"https:\/\/wvefouvvpp.wpdns.site\/?post_type=product&#038;p=1186"},"modified":"2026-10-16T02:55:52","modified_gmt":"2026-10-16T02:55:52","slug":"sfz11-35kv-loaded-oil-immersed-power-transformer","status":"publish","type":"product","link":"https:\/\/lbajiele.com\/fr\/product\/sfz11-35kv-loaded-oil-immersed-power-transformer\/","title":{"rendered":"Transformateur de puissance immerg\u00e9 dans l'huile en charge SFZ11-35kV"},"content":{"rendered":"<h2><strong><b>Signification du mod\u00e8le<\/b><\/strong><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1188\" src=\"https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/3.webp\" alt=\"\" width=\"1200\" height=\"186\" srcset=\"https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/3.webp 1200w, https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/3-300x47.webp 300w, https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/3-1024x159.webp 1024w, https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/3-768x119.webp 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/p>\n<h2><strong><b>Champ d'application<\/b><\/strong><\/h2>\n<p>Le transformateur immerg\u00e9 dans l'huile SFZ11-1600-31500\/35 convient aux syst\u00e8mes \u00e9lectriques \u00e0 courant alternatif de 50 Hz, avec une tension de service nominale de 35 kV, en tant qu'\u00e9quipement de transformation pour les petites et moyennes sous-stations.<\/p>\n<h2><strong><b>Noyau de fer<\/b><\/strong><\/h2>\n<p>Le noyau est en t\u00f4le d'acier au silicium lamin\u00e9e \u00e0 froid \u00e0 orientation magn\u00e9tique \u00e0 haute perm\u00e9abilit\u00e9. Le noyau de fer est un noyau de fer conventionnel, un noyau de fer de type \u00e0 empilage de joints enti\u00e8rement oblique, la colonne du noyau de fer a une section transversale circulaire \u00e0 plusieurs \u00e9tages, et le joug en fer et le noyau de fer ont une section transversale \u00e9gale.<\/p>\n<h2><strong><b>Enroulement<\/b><\/strong><\/h2>\n<p>Les enroulements sont des bobines concentriques ; l'enroulement \u00e0 haute tension comporte une prise n\u00e9cessaire pour la tension de prise, qui est achemin\u00e9e vers le changeur de prises. Le commutateur est install\u00e9 sur le couvercle du bo\u00eetier, et la tension de prise ne peut \u00eatre modifi\u00e9e qu'apr\u00e8s coupure de l'alimentation \u00e9lectrique.<\/p>\n<h2><strong><b>Dispositif de protection de s\u00e9curit\u00e9<\/b><\/strong><\/h2>\n<p>Le transformateur est \u00e9quip\u00e9 d'un relais gaz et d'une soupape de d\u00e9charge de pression.<\/p>\n<h2><strong><b>Dispositif de protection contre l'huile<\/b><\/strong><\/h2>\n<p>Tous les transformateurs sont \u00e9quip\u00e9s de conservateurs d'huile, et une extr\u00e9mit\u00e9 est munie d'un indicateur de niveau d'huile ;<\/p>\n<p>Un dessiccateur avec joint \u00e0 huile doit \u00eatre install\u00e9 sur le conservateur d'huile du transformateur.;<\/p>\n<h2><strong><b>Appareil de mesure de la temp\u00e9rature de l'huile<\/b><\/strong><\/h2>\n<p>Les transformateurs sont tous \u00e9quip\u00e9s d'un porte-thermom\u00e8tre en verre. Le porte-thermom\u00e8tre est situ\u00e9 sur le dessus de la cuve d'huile et plonge dans l'huile de 120\u00b110 mm ;<\/p>\n<p>Les transformateurs de 10 000 kVA et plus sont \u00e9quip\u00e9s de thermom\u00e8tres indicateurs ext\u00e9rieurs ;<\/p>\n<h2><strong><b>Bac d'huile de transformateur et ses accessoires<\/b><\/strong><\/h2>\n<p>Le transformateur n'est g\u00e9n\u00e9ralement pas fourni avec la voiture, et la position de soudage du support inf\u00e9rieur doit \u00eatre conforme aux dispositions de la norme GB 6451 ;<\/p>\n<p>La paroi inf\u00e9rieure du r\u00e9servoir d'huile est \u00e9quip\u00e9e d'une vanne de pr\u00e9l\u00e8vement d'huile, et la partie inf\u00e9rieure de la cuve d'huile du transformateur est \u00e9quip\u00e9e d'une vanne de vidange d'huile suffisamment grande.<\/p>\n<h2><strong><b>Conditions de travail<\/b><\/strong><\/h2>\n<p>Hauteur d'installation : altitude maximale de 1000 m<\/p>\n<p>Temp\u00e9rature ambiante : -40\u2103 ~ +40\u2103<\/p>\n<h2><strong><b>Transformateur de puissance immerg\u00e9 dans l'huile en charge<\/b><\/strong><\/h2>\n<table width=\"726\">\n<tbody>\n<tr>\n<td rowspan=\"2\" width=\"80\">mod\u00e8le<\/td>\n<td rowspan=\"2\" width=\"50\">Class\u00e9<br \/>\nCapacit\u00e9<br \/>\n(kVA)<\/td>\n<td colspan=\"2\" width=\"156\">Tension assign\u00e9e (kV)<\/td>\n<td rowspan=\"2\" width=\"65\">connexion<br \/>\ngroupes<\/td>\n<td colspan=\"2\" width=\"76\">Pertes(kW)<\/td>\n<td rowspan=\"2\" width=\"48\">sans frais de chargement<br \/>\nactuel<br \/>\n(%)<\/td>\n<td rowspan=\"2\" width=\"66\">imp\u00e9dance<br \/>\ntension<br \/>\n(%)<\/td>\n<td colspan=\"4\" width=\"185\">poids (kg)<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">haute pression<br \/>\n(kV)<\/td>\n<td width=\"76\">basse pression<br \/>\n(kV)<\/td>\n<td width=\"35\">non<br \/>\ncharger<\/td>\n<td width=\"41\">charger<\/td>\n<td width=\"42\">huile<br \/>\npoids<\/td>\n<td width=\"42\">total<br \/>\npoids<\/td>\n<td width=\"44\">Ajouter de l'huile<br \/>\npoids<\/td>\n<td width=\"57\">Transport<br \/>\npoids<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-1600\/35<\/td>\n<td width=\"50\">1600<\/td>\n<td rowspan=\"7\" width=\"80\">35\u00b1<br \/>\n3\u00d72.5%<br \/>\n38.5\u00b1<br \/>\n3\u00d72.5%<\/td>\n<td rowspan=\"7\" width=\"76\">11<br \/>\n10.5<br \/>\n6.6<br \/>\n6.3<\/td>\n<td rowspan=\"7\" width=\"65\">Ynd11<\/td>\n<td width=\"35\">2.2<\/td>\n<td width=\"41\">16.2<\/td>\n<td width=\"48\">0.9<\/td>\n<td width=\"66\">6.5<\/td>\n<td width=\"42\">1.8<\/td>\n<td width=\"42\">6.24<\/td>\n<td width=\"44\">0.45<\/td>\n<td width=\"57\">4.89<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-2000\/35<\/td>\n<td width=\"50\">2000<\/td>\n<td width=\"35\">2.9<\/td>\n<td width=\"41\">18.7<\/td>\n<td width=\"48\">0.9<\/td>\n<td width=\"66\">6.5<\/td>\n<td width=\"42\">2.04<\/td>\n<td width=\"42\">7.04<\/td>\n<td width=\"44\">0.56<\/td>\n<td width=\"57\">6.24<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-2500\/35<\/td>\n<td width=\"50\">2500<\/td>\n<td width=\"35\">3.4<\/td>\n<td width=\"41\">21.7<\/td>\n<td width=\"48\">0.9<\/td>\n<td width=\"66\">6.5<\/td>\n<td width=\"42\">2.2<\/td>\n<td width=\"42\">8.1<\/td>\n<td width=\"44\">0.63<\/td>\n<td width=\"57\">7.1<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-3150\/35<\/td>\n<td width=\"50\">3150<\/td>\n<td width=\"35\">4<\/td>\n<td width=\"41\">26<\/td>\n<td width=\"48\">0.81<\/td>\n<td width=\"66\">7<\/td>\n<td width=\"42\">2.475<\/td>\n<td width=\"42\">9.3<\/td>\n<td width=\"44\">0.72<\/td>\n<td width=\"57\">713<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-4000\/35<\/td>\n<td width=\"50\">4000<\/td>\n<td width=\"35\">4.8<\/td>\n<td width=\"41\">30.6<\/td>\n<td width=\"48\">0.81<\/td>\n<td width=\"66\">7<\/td>\n<td width=\"42\">2.71<\/td>\n<td width=\"42\">11.4<\/td>\n<td width=\"44\">0.78<\/td>\n<td width=\"57\">8.1<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-5000\/35<\/td>\n<td width=\"50\">5000<\/td>\n<td width=\"35\">5.8<\/td>\n<td width=\"41\">36<\/td>\n<td width=\"48\">0.76<\/td>\n<td width=\"66\">7<\/td>\n<td width=\"42\">3.1<\/td>\n<td width=\"42\">12.9<\/td>\n<td width=\"44\">0.85<\/td>\n<td width=\"57\">9.1<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-6300\/35<\/td>\n<td width=\"50\">6300<\/td>\n<td width=\"35\">7<\/td>\n<td width=\"41\">38.7<\/td>\n<td width=\"48\">0.76<\/td>\n<td width=\"66\">7.5<\/td>\n<td width=\"42\">3.6<\/td>\n<td width=\"42\">15.4<\/td>\n<td width=\"44\">0.86<\/td>\n<td width=\"57\">12.1<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-8000\/35<\/td>\n<td width=\"50\">8000<\/td>\n<td rowspan=\"7\" width=\"80\">35\u00b1<br \/>\n3\u00d72.5%<br \/>\n38.5\u00b1<br \/>\n3\u00d72.5%<\/td>\n<td rowspan=\"7\" width=\"76\">10.5<br \/>\n6.3<\/td>\n<td rowspan=\"7\" width=\"65\">Yd11<\/td>\n<td width=\"35\">9.8<\/td>\n<td width=\"41\">42.6<\/td>\n<td width=\"48\">0.66<\/td>\n<td width=\"66\">7.5<\/td>\n<td width=\"42\">4.5<\/td>\n<td width=\"42\">17.8<\/td>\n<td width=\"44\">0.9<\/td>\n<td width=\"57\">15.4<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-10000\/35<\/td>\n<td width=\"50\">10000<\/td>\n<td width=\"35\">11.6<\/td>\n<td width=\"41\">50.5<\/td>\n<td width=\"48\">0.63<\/td>\n<td width=\"66\">7.5<\/td>\n<td width=\"42\">4.6<\/td>\n<td width=\"42\">19.3<\/td>\n<td width=\"44\">1<\/td>\n<td width=\"57\">17.2<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-12500\/35<\/td>\n<td width=\"50\">12500<\/td>\n<td width=\"35\">12.8<\/td>\n<td width=\"41\">59.9<\/td>\n<td width=\"48\">0.63<\/td>\n<td width=\"66\">8<\/td>\n<td width=\"42\">5.9<\/td>\n<td width=\"42\">24.7<\/td>\n<td width=\"44\">1.2<\/td>\n<td width=\"57\">18.7<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-16000\/35<\/td>\n<td width=\"50\">16000<\/td>\n<td width=\"35\">13.8<\/td>\n<td width=\"41\">68<\/td>\n<td width=\"48\">0.8<\/td>\n<td width=\"66\">8<\/td>\n<td width=\"42\">7.9<\/td>\n<td width=\"42\">32.5<\/td>\n<td width=\"44\">2<\/td>\n<td width=\"57\">27.1<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-20000\/35<\/td>\n<td width=\"50\">20000<\/td>\n<td width=\"35\">17.8<\/td>\n<td width=\"41\">84.6<\/td>\n<td width=\"48\">0.72<\/td>\n<td width=\"66\">8<\/td>\n<td width=\"42\">78.9<\/td>\n<td width=\"42\">36.7<\/td>\n<td width=\"44\">2.1<\/td>\n<td width=\"57\">30.9<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-25000\/35<\/td>\n<td width=\"50\">25000<\/td>\n<td width=\"35\">18.6<\/td>\n<td width=\"41\">99.6<\/td>\n<td width=\"48\">0.72<\/td>\n<td width=\"66\">8<\/td>\n<td width=\"42\">8.1<\/td>\n<td width=\"42\">40.3<\/td>\n<td width=\"44\">2.2<\/td>\n<td width=\"57\">35.4<\/td>\n<\/tr>\n<tr>\n<td width=\"80\">SZ11-31500\/35<\/td>\n<td width=\"50\">31500<\/td>\n<td width=\"35\">20.4<\/td>\n<td width=\"41\">123.8<\/td>\n<td width=\"48\">0.64<\/td>\n<td width=\"66\">10<\/td>\n<td width=\"42\">8.2<\/td>\n<td width=\"42\">42.3<\/td>\n<td width=\"44\">2.3<\/td>\n<td width=\"57\">36.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Remarque : Les dimensions et le poids fournis sont uniquement donn\u00e9s \u00e0 titre de r\u00e9f\u00e9rence pour la conception et la s\u00e9lection, et les dimensions et le poids finaux sont soumis aux plans de produits de notre entreprise.<\/p>","protected":false},"excerpt":{"rendered":"<p>Le transformateur immerg\u00e9 dans l'huile SFZ11-1600-31500\/35 convient aux syst\u00e8mes \u00e9lectriques \u00e0 courant alternatif de 50 Hz, avec une tension de service nominale de 35 kV, en tant qu'\u00e9quipement de transformation pour les petites et moyennes sous-stations.<\/p>","protected":false},"featured_media":1187,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[102,25],"product_tag":[],"class_list":["post-1186","product","type-product","status-publish","has-post-thumbnail","product_cat-power-transformer","product_cat-transformers","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/product\/1186","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/comments?post=1186"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/media\/1187"}],"wp:attachment":[{"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/media?parent=1186"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/product_brand?post=1186"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/product_cat?post=1186"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/product_tag?post=1186"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}