{"id":1217,"date":"2026-04-06T15:14:57","date_gmt":"2026-04-06T07:14:57","guid":{"rendered":"https:\/\/wvefouvvpp.wpdns.site\/?post_type=product&#038;p=1217"},"modified":"2026-09-23T18:30:07","modified_gmt":"2026-09-23T18:30:07","slug":"sgb-environment-friendly-dry-type-transformer","status":"publish","type":"product","link":"https:\/\/lbajiele.com\/fr\/product\/sgb-environment-friendly-dry-type-transformer\/","title":{"rendered":"Transformateur sec respectueux de l'environnement SG(B)"},"content":{"rendered":"<p>Pour une vue plus globale, consultez notre <a href=\"https:\/\/lbajiele.com\/fr\/blog\/dry-type-transformer-guide\/\">dry-type transformer cooling and selection overview<\/a>.<\/p>\n<h2><strong><b>Aper\u00e7u<\/b><\/strong><\/h2>\n<p>Le transformateur de puissance de type sec isol\u00e9 de classe H SG (B) pr\u00e9sente une forte r\u00e9sistance aux chocs thermiques, une capacit\u00e9 de surcharge \u00e9lev\u00e9e, une r\u00e9sistance aux flammes, une haute r\u00e9sistance au feu, de faibles pertes, de faibles d\u00e9charges partielles, un faible bruit, aucune production de gaz nocifs, aucune pollution environnementale, une insensibilit\u00e9 \u00e0 l'humidit\u00e9 et \u00e0 la poussi\u00e8re, une petite taille, pas de fissuration et un entretien facile. Par cons\u00e9quent, il est particuli\u00e8rement adapt\u00e9 \u00e0 une utilisation dans des environnements difficiles pr\u00e9sentant des exigences \u00e9lev\u00e9es en mati\u00e8re de pr\u00e9vention des incendies, de fortes fluctuations de charge, ainsi que des conditions de salet\u00e9 et d'humidit\u00e9. Tels que les a\u00e9roports, les centrales \u00e9lectriques, les op\u00e9rations m\u00e9tallurgiques, les h\u00f4pitaux, les IGH (immeubles de grande hauteur), les centres commerciaux, les zones r\u00e9sidentielles dens\u00e9ment peupl\u00e9es, ainsi que les environnements sp\u00e9ciaux tels que la p\u00e9trochimie, les centrales nucl\u00e9aires et les sous-marins nucl\u00e9aires.<\/p>\n<h2><strong><b>Noyau de fer<\/b><\/strong><\/h2>\n<p>Le noyau en fer est compos\u00e9 de t\u00f4les d'acier au silicium de haute qualit\u00e9 \u00e0 haute conductivit\u00e9 magn\u00e9tique, \u00e0 grains orient\u00e9s et import\u00e9es, empil\u00e9es ensemble. La structure de joint enti\u00e8rement inclin\u00e9e \u00e0 45\u00b0 adopte un dispositif de fixation \u00e9lastique entre l'enroulement et le noyau en fer, ce qui permet au transformateur d'avoir de faibles pertes \u00e0 vide et un faible bruit.<\/p>\n<p>La surface du noyau de fer est trait\u00e9e avec une technologie sp\u00e9ciale, ce qui permet non seulement de r\u00e9duire le bruit du transformateur, mais aussi d'emp\u00eacher le noyau de fer de rouiller pendant son fonctionnement.<\/p>\n<p>Le noyau de fer est mod\u00e9r\u00e9ment serr\u00e9 par une vis de tirage, et les parties de serrage sup\u00e9rieure et inf\u00e9rieure sont reli\u00e9es par une plaque de tirage et fix\u00e9es \u00e0 la base en un tout. L'enroulement est fix\u00e9 par des coussinets \u00e9lastiques, et la structure tampon peut r\u00e9duire le niveau de vibration et le bruit de l'enroulement.<\/p>\n<h2><strong><b>Bobines haute et basse tension<\/b><\/strong><\/h2>\n<p>Les enroulements haute et basse tension sont fabriqu\u00e9s en mat\u00e9riau isolant Nomex et sont impr\u00e9gn\u00e9s \u00e0 plusieurs reprises de peinture d'impr\u00e9gnation sans solvant \u00e0 l'aide d'un \u00e9quipement de pressurisation sous vide VPI, puis cuits et polym\u00e9ris\u00e9s \u00e0 haute temp\u00e9rature \u00e0 plusieurs reprises. L'enroulement haute tension adopte une structure continue offrant une r\u00e9sistance m\u00e9canique \u00e9lev\u00e9e et de bonnes conditions de dissipation thermique, \u00e9vitant ainsi les inconv\u00e9nients des enroulements cylindriques multicouches tels qu'une tension inter-couches \u00e9lev\u00e9e, une faible capacit\u00e9 de dissipation thermique, un claquage thermique facile et une faible r\u00e9sistance m\u00e9canique, am\u00e9liorant ainsi la fiabilit\u00e9 du fonctionnement du produit ; l'enroulement basse tension adopte une structure en spirale \u00e0 fort courant avec une feuille ou un conduit d'air longitudinal. L'enroulement impr\u00e9gn\u00e9 poss\u00e8de une excellente r\u00e9sistance \u00e0 l'humidit\u00e9 et peut supporter les impacts plus efficacement. Il ne pr\u00e9sente ni fissures ni d\u00e9charges partielles, et il est facile \u00e0 s\u00e9cher, \u00e0 d\u00e9composer et \u00e0 recycler apr\u00e8s sa dur\u00e9e de vie, prot\u00e9geant ainsi l'environnement.<\/p>\n<h2><strong><b>Bo\u00eetier<\/b><\/strong><\/h2>\n<p>Si l'utilisateur le demande, notre entreprise peut fournir des enveloppes avec des niveaux de protection IP20 et IP23.<\/p>\n<p>La signification du niveau de protection de l'enveloppe IP20 est qu'aucun corps \u00e9tranger solide d'un diam\u00e8tre de 12 mm n'est autoris\u00e9 \u00e0 p\u00e9n\u00e9trer.<\/p>\n<p>Pour assurer la circulation de l'air de refroidissement, le fond et le sommet de la coque sont constitu\u00e9s de plaques grillag\u00e9es.<\/p>\n<p>Le degr\u00e9 de protection de l'enveloppe IP23 a non seulement la m\u00eame signification que l'IP20, mais il sert \u00e9galement \u00e0 emp\u00eacher l'eau de p\u00e9n\u00e9trer \u00e0 moins de 60 degr\u00e9s de la verticale.<\/p>\n<h2><strong><b>Protection contre la surchauffe<\/b><\/strong><\/h2>\n<p>Pour prendre des mesures de protection contre la surchauffe des enroulements, les transformateurs de type sec SG(B)10 de 315 kVA et plus sont \u00e9quip\u00e9s d'un dispositif de protection \u00e0 affichage de la temp\u00e9rature. Ce dispositif utilise des \u00e9l\u00e9ments de d\u00e9tection de temp\u00e9rature int\u00e9gr\u00e9s dans l'enroulement basse tension comme source de signal pour l'instrument d'affichage num\u00e9rique. Lorsque la temp\u00e9rature \u00e0 l'int\u00e9rieur de l'enroulement basse tension change, l'instrument d'affichage num\u00e9rique de temp\u00e9rature affiche une nouvelle valeur de temp\u00e9rature et ex\u00e9cute des fonctions de commande et d'alarme bas\u00e9es sur cette valeur de temp\u00e9rature afin de prot\u00e9ger le transformateur.<\/p>\n<h2><strong><b>Capacit\u00e9 de surcharge<\/b><\/strong><\/h2>\n<p>Le transformateur de puissance \u00e0 sec SG (B) 10 int\u00e8gre une nouvelle conception, de nouveaux mat\u00e9riaux et de nouveaux proc\u00e9d\u00e9s, offrant de bonnes conditions de dissipation thermique, une longue dur\u00e9e de vie thermique et une capacit\u00e9 de surcharge extr\u00eamement \u00e9lev\u00e9e. Il peut fonctionner de mani\u00e8re s\u00fbre et fiable pendant une longue p\u00e9riode en cas de surcharge de type 120%. Dans l&#x27;ancien environnement 23, aucun refroidissement par ventilateur n&#x27;est n\u00e9cessaire et il peut tout de m\u00eame fonctionner \u00e0 pleine charge pendant une longue p\u00e9riode.<\/p>\n<h2><strong><b>S\u00e9curiser<\/b><\/strong><\/h2>\n<p>Le SG (B) 10 est le transformateur \u00e0 sec offrant les meilleures performances de s\u00e9curit\u00e9 actuellement disponibles sur le march\u00e9. Tous les mat\u00e9riaux d&#x27;isolation sont incombustibles, auto-extinguibles et non toxiques, et contiennent moins de 10% de substances inflammables par rapport aux produits moul\u00e9s \u00e0 l&#x27;\u00e9poxy.\u00a0Ils br\u00fblent longtemps \u00e0 une temp\u00e9rature \u00e9lev\u00e9e de 800 \u2103 sans produire de fum\u00e9es toxiques, ce qui permet de pallier le probl\u00e8me des gaz toxiques g\u00e9n\u00e9r\u00e9s lors de la combustion des transformateurs moul\u00e9s en \u00e9poxy. Le nouveau produit SG (B) 10 offre des performances sup\u00e9rieures dans les applications pr\u00e9sentant des exigences de s\u00e9curit\u00e9 \u00e9lev\u00e9es, dans des conditions humides et chaudes, ainsi que dans des environnements mal ventil\u00e9s, tels que les secteurs de l\u2019\u00e9nergie, du m\u00e9tro, de la marine, de la chimie et de la m\u00e9tallurgie.<\/p>\n<h2><strong><b>Fiable<\/b><\/strong><\/h2>\n<p>La conception sp\u00e9ciale de la bobine, le proc\u00e9d\u00e9 et les mat\u00e9riaux du nouveau produit SG(B)10 offrent d'excellentes performances de protection tridimensionnelle (protection contre l'humidit\u00e9, la moisissure et le brouillard salin), une meilleure r\u00e9sistance aux chocs thermiques, aucune fissure et aucune d\u00e9charge partielle. Le syst\u00e8me d'isolation \u00e0 base de Nomex maintient d'excellentes performances \u00e9lectriques et m\u00e9caniques tout au long de la dur\u00e9e de vie du transformateur. Le mat\u00e9riau Nomex n'est pas sujet au vieillissement, r\u00e9siste au retrait et \u00e0 la compression, et poss\u00e8de une forte \u00e9lasticit\u00e9, ce qui garantit que la bobine du transformateur reste \u00e9troitement structur\u00e9e m\u00eame apr\u00e8s des ann\u00e9es d'utilisation et peut r\u00e9sister \u00e0 la pression des courts-circuits.<\/p>\n<h2><strong><b>Prot\u00e9ger le bo\u00eetier et les barres omnibus<\/b><\/strong><\/h2>\n<p>Le transformateur de type sec \u00e0 syst\u00e8me d'isolation Nomex est capable de r\u00e9sister \u00e0 l'invasion de l'humidit\u00e9.<\/p>\n<p>Adoption d'\u00e9quipements VPI de pointe et de la technologie d'impr\u00e9gnation sous vide.<\/p>\n<p>La peinture d'impr\u00e9gnation de haute qualit\u00e9 reconnue par U peut fonctionner en continu pendant une longue p\u00e9riode \u00e0 des temp\u00e9ratures de 180 \u00b0C et plus.<\/p>\n<p>Le papier Nomex est enti\u00e8rement impr\u00e9gn\u00e9 de vernis d'impr\u00e9gnation.<\/p>\n<h2><strong><b>Plus petit volume et poids plus l\u00e9ger<\/b><\/strong><\/h2>\n<p>Le nouveau produit SG (B) 10 utilise du papier DuPont Nomex comme mat\u00e9riau isolant principal et l'utilise comme syst\u00e8me d'isolation hybride au point le plus chaud du transformateur, r\u00e9duisant ainsi sa taille et son poids par rapport aux transformateurs coul\u00e9s en r\u00e9sine \u00e9poxy de m\u00eame capacit\u00e9.<\/p>\n<h2><strong><b>Protection de l'environnement<\/b><\/strong><\/h2>\n<p>Le nouveau produit SG (B) 10 peut \u00eatre d\u00e9compos\u00e9 et recycl\u00e9 apr\u00e8s sa dur\u00e9e de vie, surmontant ainsi le d\u00e9faut des transformateurs de type sec coul\u00e9s en r\u00e9sine \u00e9poxy qui ne peuvent pas \u00eatre d\u00e9compos\u00e9s et polluent l'environnement en raison de la solidification et de la fusion de la r\u00e9sine et de la fibre de verre en un tout apr\u00e8s leur dur\u00e9e de vie.<\/p>\n<h2><strong><b>Signification du mod\u00e8le<\/b><\/strong><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1219\" src=\"https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/2-1.webp\" alt=\"\" width=\"1200\" height=\"186\" srcset=\"https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/2-1.webp 1200w, https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/2-1-300x47.webp 300w, https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/2-1-1024x159.webp 1024w, https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/2-1-768x119.webp 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/p>\n<h2><strong><b>Fil de connexion<\/b><\/strong><\/h2>\n<p>La borne de sortie haute tension est fix\u00e9e sur la partie sup\u00e9rieure de l'enroulement, et la prise est situ\u00e9e au milieu de l'enroulement. En cas de panne de courant, la prise est chang\u00e9e par l'interm\u00e9diaire d'une pi\u00e8ce de raccordement pour r\u00e9gler la tension de sortie.<\/p>\n<p>La borne de d\u00e9part basse tension est une bande conductrice de type plat, qui est connect\u00e9e de mani\u00e8re fiable \u00e0 la bande de d\u00e9part par des boulons.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1220\" src=\"https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/Lead-wire.webp\" alt=\"\" width=\"1200\" height=\"806\" srcset=\"https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/Lead-wire.webp 1200w, https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/Lead-wire-300x202.webp 300w, https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/Lead-wire-1024x688.webp 1024w, https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/Lead-wire-768x516.webp 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/p>\n<h2><strong><b>Condition normale<\/b><\/strong><\/h2>\n<p>Selon l'article 1.2 de la norme GB6450-1986 \u201c Transformateurs de type sec \u201d, lorsque la temp\u00e9rature maximale de l'environnement est sup\u00e9rieure \u00e0 40 \u2103 et que l'altitude est de 1000 m, elle doit \u00eatre corrig\u00e9e conform\u00e9ment aux dispositions pertinentes de la norme nationale. Demander \u00e0 l'utilisateur de pr\u00e9ciser lors de la commande.<\/p>\n<h2><strong><b>Normes et param\u00e8tres associ\u00e9s<\/b><\/strong><\/h2>\n<ul>\n<li>GB1094.11-2007 \u201cTransformateurs de type sec\u201d<\/li>\n<li>GB\/T 10228-1997 \u201d Param\u00e8tres techniques et exigences pour les transformateurs de puissance de type sec \u00bb<\/li>\n<li>GB\/T 17211-1998 \u201c Guide de charge pour les transformateurs de puissance de type sec \u201d<\/li>\n<li>JB\/T10088-2004 \u201c Niveau sonore des transformateurs de puissance de 6-220 kV \u201d<\/li>\n<li>GB4208-1993 \u201c Degr\u00e9s de protection procur\u00e9s par les enveloppes (Code IP) \u201d<\/li>\n<\/ul>\n<h2><strong><b>Dimensions d'encombrement et d'installation<\/b><\/strong><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1221\" src=\"https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/2Appearance-and-installation-dimensions.webp\" alt=\"\" width=\"1200\" height=\"1093\" srcset=\"https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/2Appearance-and-installation-dimensions.webp 1200w, https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/2Appearance-and-installation-dimensions-300x273.webp 300w, https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/2Appearance-and-installation-dimensions-1024x933.webp 1024w, https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/2Appearance-and-installation-dimensions-768x700.webp 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/p>\n<h2><strong><b>Param\u00e8tres techniques<\/b><\/strong><\/h2>\n<h3><strong><b>Transformateur de type sec \u00e9cologique 10 kV SG (B) 11H<\/b><\/strong><\/h3>\n<table style=\"border-collapse: collapse; width: 474.02pt;\" border=\"0\" width=\"632\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 49.50pt; width: 24.75pt;\" rowspan=\"2\" width=\"33\" height=\"66\">Class\u00e9<br \/>\ncapacit\u00e9<br \/>\n(kVA)<\/td>\n<td class=\"et3\" style=\"width: 94.50pt;\" colspan=\"3\" width=\"126\">Combinaison de tensions<br \/>\net plage de prises (kV)<\/td>\n<td class=\"et4\" style=\"width: 33.75pt;\" rowspan=\"2\" width=\"45\">connexion<br \/>\nsymbole<\/td>\n<td class=\"et4\" style=\"width: 21.75pt;\" rowspan=\"2\" width=\"29\">Non<br \/>\ncharger<br \/>\nperte<br \/>\n(kW)<\/td>\n<td class=\"et3\" style=\"width: 81.75pt;\" colspan=\"3\" width=\"109\">Pertes en charge pour diff\u00e9rentes isolations<br \/>\ntemp\u00e9ratures du syst\u00e8me (Kw)<\/td>\n<td class=\"et4\" style=\"width: 22.50pt;\" rowspan=\"2\" width=\"30\">Non<br \/>\ncharger<br \/>\nactuel<br \/>\n(%)<\/td>\n<td class=\"et4\" style=\"width: 32.25pt;\" rowspan=\"2\" width=\"43\">Court<br \/>\ncircuit<br \/>\nimp\u00e9dance<br \/>\n(%)<\/td>\n<td class=\"et4\" style=\"width: 21.75pt;\" rowspan=\"2\" width=\"29\">Poids<br \/>\n(kg)<\/td>\n<td class=\"et4\" style=\"width: 53.25pt;\" rowspan=\"2\" width=\"71\">Dimensions (mm)<br \/>\n(L en longueur, B en<br \/>\nlargeur et H en<br \/>\nhauteur<\/td>\n<td class=\"et4\" style=\"width: 34.50pt;\" rowspan=\"2\" width=\"46\">Installation<br \/>\ntaille<\/td>\n<td class=\"et4\" style=\"width: 53.25pt;\" rowspan=\"2\" width=\"71\">Avec la taille de la coque<br \/>\n(L\u00d7l\u00d7h)<\/td>\n<\/tr>\n<tr style=\"height: 36.00pt;\">\n<td class=\"et6\" style=\"width: 26.25pt;\" width=\"35\">Haut<br \/>\nPression<br \/>\n(kV)<\/td>\n<td class=\"et6\" style=\"width: 42.00pt;\" width=\"56\">Haute tension<br \/>\nplage de division<br \/>\nd'acceptation<br \/>\n(%)<\/td>\n<td class=\"et6\" style=\"width: 26.25pt;\" width=\"35\">Faible<br \/>\nPression<br \/>\n(kV)<\/td>\n<td class=\"et6\" style=\"width: 28.50pt;\" width=\"38\">130 \u00b0C (B)<br \/>\n(100 \u00b0C)<\/td>\n<td class=\"et6\" style=\"width: 28.50pt;\" width=\"38\">155 \u00b0C (B)<br \/>\n(120 \u00b0C)<\/td>\n<td class=\"et6\" style=\"width: 24.75pt;\" width=\"33\">80 \u00b0C (B)<br \/>\n(145\u00b0C)<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et7\" style=\"height: 13.50pt;\" height=\"18\">100<\/td>\n<td class=\"et6\" style=\"width: 26.25pt;\" rowspan=\"15\" width=\"35\">6<br \/>\n6.3<br \/>\n6.6<br \/>\n10<br \/>\n10.5<br \/>\n11<\/td>\n<td class=\"et6\" style=\"width: 42.00pt;\" rowspan=\"2\" width=\"56\">\u00b12,5<br \/>\n\u00b15<\/td>\n<td class=\"et8\" rowspan=\"15\">0.4<\/td>\n<td class=\"et6\" style=\"width: 33.75pt;\" rowspan=\"15\" width=\"45\">Dyn11<br \/>\nYyn0<\/td>\n<td class=\"et9\">0.36<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">1.69<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et10\" rowspan=\"8\">4<\/td>\n<td class=\"et9\">590<\/td>\n<td class=\"et9\">850\u00d7600\u00d7830<\/td>\n<td class=\"et9\">400\/450<\/td>\n<td class=\"et9\">1250\u00d71000\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et7\" style=\"height: 13.50pt;\" height=\"18\">125<\/td>\n<td class=\"et9\">0.42<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">1.98<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">650<\/td>\n<td class=\"et9\">870\u00d7650\u00d7890<\/td>\n<td class=\"et9\">550\/550<\/td>\n<td class=\"et9\">1300\u00d71000\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et7\" style=\"height: 13.50pt;\" height=\"18\">160<\/td>\n<td class=\"et6\" style=\"width: 42.00pt;\" rowspan=\"13\" width=\"56\">\u00b12\u00d72,5<br \/>\n\u00b15<\/td>\n<td class=\"et9\">0.48<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">2.28<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">800<\/td>\n<td class=\"et9\">900\u00d7710\u00d7930<\/td>\n<td class=\"et9\">550\/550<\/td>\n<td class=\"et9\">1300\u00d71100\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et7\" style=\"height: 13.50pt;\" height=\"18\">200<\/td>\n<td class=\"et9\">0.56<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">2.71<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">880<\/td>\n<td class=\"et9\">940\u00d7750\u00d7980<\/td>\n<td class=\"et9\">550\/660<\/td>\n<td class=\"et9\">1350\u00d71100\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td class=\"et7\" style=\"height: 14.25pt;\" height=\"19\">250<\/td>\n<td class=\"et9\">0.65<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">2.96<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">1050<\/td>\n<td class=\"et9\">990\u00d7770\u00d71030<\/td>\n<td class=\"et9\">660\/660<\/td>\n<td class=\"et9\">1400\u00d71150\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et7\" style=\"height: 13.50pt;\" height=\"18\">315<\/td>\n<td class=\"et9\">0.79<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">3.73<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">1260<\/td>\n<td class=\"et9\">1020\u00d7790\u00d71080<\/td>\n<td class=\"et9\">660\/660<\/td>\n<td class=\"et9\">1450\u00d71150\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et7\" style=\"height: 13.50pt;\" height=\"18\">400<\/td>\n<td class=\"et9\">0.88<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">4.28<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">1570<\/td>\n<td class=\"et9\">1060\u00d7880\u00d71180<\/td>\n<td class=\"et9\">660\/820<\/td>\n<td class=\"et9\">1450\u00d71200\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et7\" style=\"height: 13.50pt;\" height=\"18\">500<\/td>\n<td class=\"et9\">1.04<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">5.23<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">1780<\/td>\n<td class=\"et9\">1090\u00d7900\u00d71220<\/td>\n<td class=\"et9\">660\/820<\/td>\n<td class=\"et9\">1500\u00d71200\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et7\" style=\"height: 13.50pt;\" height=\"18\">630<\/td>\n<td class=\"et9\">1.17<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">6.4<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et10\" rowspan=\"7\">6<\/td>\n<td class=\"et9\">1860<\/td>\n<td class=\"et9\">1200\u00d7920\u00d71150<\/td>\n<td class=\"et9\">820\/820<\/td>\n<td class=\"et9\">1600\u00d71200\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et7\" style=\"height: 13.50pt;\" height=\"18\">800<\/td>\n<td class=\"et9\">1.37<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">7.46<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">2180<\/td>\n<td class=\"et9\">1260\u00d7920\u00d71200<\/td>\n<td class=\"et9\">820\/820<\/td>\n<td class=\"et9\">1650\u00d71200\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et7\" style=\"height: 13.50pt;\" height=\"18\">1000<\/td>\n<td class=\"et9\">1.59<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">8.76<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">2590<\/td>\n<td class=\"et9\">1320\u00d7950\u00d71250<\/td>\n<td class=\"et9\">820\/820<\/td>\n<td class=\"et9\">1750\u00d71300\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et7\" style=\"height: 13.50pt;\" height=\"18\">1250<\/td>\n<td class=\"et9\">1.88<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">10.3<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">2980<\/td>\n<td class=\"et9\">1350\u00d7980\u00d71320<\/td>\n<td class=\"et9\">820\/820<\/td>\n<td class=\"et9\">1750\u00d71350\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et7\" style=\"height: 13.50pt;\" height=\"18\">1600<\/td>\n<td class=\"et9\">2.2<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">12.5<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">3580<\/td>\n<td class=\"et9\">1400\u00d71120\u00d71400<\/td>\n<td class=\"et9\">1070\/1070<\/td>\n<td class=\"et9\">1800\u00d71400\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et7\" style=\"height: 13.50pt;\" height=\"18\">2000<\/td>\n<td class=\"et9\">2.75<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">15.5<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">4070<\/td>\n<td class=\"et9\">1440\u00d71120\u00d71520<\/td>\n<td class=\"et9\">1070\/1070<\/td>\n<td class=\"et9\">1850\u00d71450\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et7\" style=\"height: 13.50pt;\" height=\"18\">2500<\/td>\n<td class=\"et9\">3.24<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">18.4<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et9\">4820<\/td>\n<td class=\"et9\">1500\u00d71120\u00d71640<\/td>\n<td class=\"et9\">1070\/1070<\/td>\n<td class=\"et9\">1900\u00d71500\u00d72200<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong><b>Transformateur de type sec \u00e9cologique SG(B) 13H 10kV<\/b><\/strong><\/h3>\n<table style=\"border-collapse: collapse; width: 474.02pt;\" border=\"0\" width=\"632\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 50.25pt; width: 24.75pt;\" rowspan=\"2\" width=\"33\" height=\"67\">Class\u00e9<br \/>\ncapacit\u00e9<br \/>\n(kVA)<\/td>\n<td class=\"et3\" style=\"width: 94.50pt;\" colspan=\"3\" width=\"126\">Combinaison de tensions<br \/>\net plage de prises (kV)<\/td>\n<td class=\"et4\" style=\"width: 33.75pt;\" rowspan=\"2\" width=\"45\">connexion<br \/>\nsymbole<\/td>\n<td class=\"et4\" style=\"width: 21.75pt;\" rowspan=\"2\" width=\"29\">Non<br \/>\ncharger<br \/>\nperte<br \/>\n(kW)<\/td>\n<td class=\"et3\" style=\"width: 81.75pt;\" colspan=\"3\" width=\"109\">Pertes en charge pour diff\u00e9rentes isolations<br \/>\ntemp\u00e9ratures du syst\u00e8me (Kw)<\/td>\n<td class=\"et4\" style=\"width: 22.50pt;\" rowspan=\"2\" width=\"30\">Non<br \/>\ncharger<br \/>\nactuel<br \/>\n(%)<\/td>\n<td class=\"et4\" style=\"width: 32.25pt;\" rowspan=\"2\" width=\"43\">Court<br \/>\ncircuit<br \/>\nimp\u00e9dance<br \/>\n(%)<\/td>\n<td class=\"et4\" style=\"width: 21.75pt;\" rowspan=\"2\" width=\"29\">Poids<br \/>\n(kg)<\/td>\n<td class=\"et4\" style=\"width: 53.25pt;\" rowspan=\"2\" width=\"71\">Dimensions (mm)<br \/>\n(L en longueur, B en<br \/>\nlargeur et H en<br \/>\nhauteur<\/td>\n<td class=\"et4\" style=\"width: 34.50pt;\" rowspan=\"2\" width=\"46\">Installation<br \/>\ntaille<\/td>\n<td class=\"et4\" style=\"width: 53.25pt;\" rowspan=\"2\" width=\"71\">Avec la taille de la coque<br \/>\n(L\u00d7l\u00d7h)<\/td>\n<\/tr>\n<tr style=\"height: 36.75pt;\">\n<td class=\"et6\" style=\"width: 26.25pt;\" width=\"35\">Haut<br \/>\nPression<br \/>\n(kV)<\/td>\n<td class=\"et6\" style=\"width: 42.00pt;\" width=\"56\">Haute tension<br \/>\nplage de division<br \/>\nd'acceptation<br \/>\n(%)<\/td>\n<td class=\"et6\" style=\"width: 26.25pt;\" width=\"35\">Faible<br \/>\nPression<br \/>\n(kV)<\/td>\n<td class=\"et6\" style=\"width: 28.50pt;\" width=\"38\">130 \u00b0C (B)<br \/>\n(100 \u00b0C)<\/td>\n<td class=\"et6\" style=\"width: 28.50pt;\" width=\"38\">155 \u00b0C (B)<br \/>\n(120 \u00b0C)<\/td>\n<td class=\"et6\" style=\"width: 24.75pt;\" width=\"33\">80 \u00b0C (B)<br \/>\n(145\u00b0C)<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td class=\"et7\" style=\"height: 14.25pt;\" height=\"19\">100<\/td>\n<td class=\"et6\" style=\"width: 26.25pt;\" rowspan=\"15\" width=\"35\">6<br \/>\n6.3<br \/>\n6.6<br \/>\n10<br \/>\n10.5<br \/>\n11<\/td>\n<td class=\"et6\" style=\"width: 42.00pt;\" rowspan=\"2\" width=\"56\">\u00b12,5<br \/>\n\u00b15<\/td>\n<td class=\"et8\" rowspan=\"15\">0.4<\/td>\n<td class=\"et6\" style=\"width: 33.75pt;\" rowspan=\"15\" width=\"45\">Dyn11<br \/>\nYyn0<\/td>\n<td class=\"et9\">0.29<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et10\">1.69<\/td>\n<td class=\"et9\">1.5<\/td>\n<td class=\"et11\" rowspan=\"8\">4<\/td>\n<td class=\"et10\">590<\/td>\n<td class=\"et10\">850\u00d7600\u00d7830<\/td>\n<td class=\"et10\">400\/450<\/td>\n<td class=\"et10\">1250\u00d71000\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td class=\"et7\" style=\"height: 14.25pt;\" height=\"19\">125<\/td>\n<td class=\"et7\">0.34<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et10\">1.98<\/td>\n<td class=\"et7\">1.3<\/td>\n<td class=\"et10\">650<\/td>\n<td class=\"et10\">870\u00d7650\u00d7890<\/td>\n<td class=\"et10\">550\/550<\/td>\n<td class=\"et10\">1300\u00d71000\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td class=\"et7\" style=\"height: 14.25pt;\" height=\"19\">160<\/td>\n<td class=\"et6\" style=\"width: 42.00pt;\" rowspan=\"13\" width=\"56\">\u00b12\u00d72,5<br \/>\n\u00b15<\/td>\n<td class=\"et7\">0.38<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et10\">2.28<\/td>\n<td class=\"et7\">13<\/td>\n<td class=\"et10\">800<\/td>\n<td class=\"et10\">900\u00d7710\u00d7930<\/td>\n<td class=\"et10\">550\/550<\/td>\n<td class=\"et10\">1300\u00d71100\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td class=\"et7\" style=\"height: 14.25pt;\" height=\"19\">200<\/td>\n<td class=\"et7\">0.45<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et10\">2.71<\/td>\n<td class=\"et7\">1.1<\/td>\n<td class=\"et10\">880<\/td>\n<td class=\"et10\">940\u00d7750\u00d7980<\/td>\n<td class=\"et10\">550\/660<\/td>\n<td class=\"et10\">1350\u00d71100\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td class=\"et7\" style=\"height: 14.25pt;\" height=\"19\">250<\/td>\n<td class=\"et7\">0.52<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et10\">2.96<\/td>\n<td class=\"et7\">11<\/td>\n<td class=\"et10\">1050<\/td>\n<td class=\"et10\">990\u00d7770\u00d71030<\/td>\n<td class=\"et10\">660\/660<\/td>\n<td class=\"et10\">1400\u00d71150\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td class=\"et7\" style=\"height: 14.25pt;\" height=\"19\">315<\/td>\n<td class=\"et7\">0.64<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et10\">3.73<\/td>\n<td class=\"et7\">1<\/td>\n<td class=\"et10\">1260<\/td>\n<td class=\"et10\">1020\u00d7790\u00d71080<\/td>\n<td class=\"et10\">660\/660<\/td>\n<td class=\"et10\">1450\u00d71150\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td class=\"et7\" style=\"height: 14.25pt;\" height=\"19\">400<\/td>\n<td class=\"et7\">0.7<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et10\">4.28<\/td>\n<td class=\"et7\">1<\/td>\n<td class=\"et10\">1570<\/td>\n<td class=\"et10\">1060\u00d7880\u00d71180<\/td>\n<td class=\"et10\">660\/820<\/td>\n<td class=\"et10\">1450\u00d71200\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td class=\"et7\" style=\"height: 14.25pt;\" height=\"19\">500<\/td>\n<td class=\"et7\">0.83<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et10\">5.23<\/td>\n<td class=\"et7\">1<\/td>\n<td class=\"et10\">1780<\/td>\n<td class=\"et10\">1090\u00d7900\u00d71220<\/td>\n<td class=\"et10\">660\/820<\/td>\n<td class=\"et10\">1500\u00d71200\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td class=\"et7\" style=\"height: 14.25pt;\" height=\"19\">630<\/td>\n<td class=\"et7\">0.94<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et10\">6.4<\/td>\n<td class=\"et7\">0.85<\/td>\n<td class=\"et11\" rowspan=\"7\">6<\/td>\n<td class=\"et10\">1860<\/td>\n<td class=\"et10\">1200\u00d7920\u00d71150<\/td>\n<td class=\"et10\">820\/820<\/td>\n<td class=\"et10\">1600\u00d71200\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td class=\"et7\" style=\"height: 14.25pt;\" height=\"19\">800<\/td>\n<td class=\"et7\">1.1<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et10\">7.46<\/td>\n<td class=\"et7\">0.85<\/td>\n<td class=\"et10\">2180<\/td>\n<td class=\"et10\">1260\u00d7920\u00d71200<\/td>\n<td class=\"et10\">820\/820<\/td>\n<td class=\"et10\">1650\u00d71200\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td class=\"et7\" style=\"height: 14.25pt;\" height=\"19\">1000<\/td>\n<td class=\"et7\">1.27<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et10\">8.76<\/td>\n<td class=\"et7\">0.85<\/td>\n<td class=\"et10\">2590<\/td>\n<td class=\"et10\">1320\u00d7950\u00d71250<\/td>\n<td class=\"et10\">820\/820<\/td>\n<td class=\"et10\">1750\u00d71300\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td class=\"et7\" style=\"height: 14.25pt;\" height=\"19\">1250<\/td>\n<td class=\"et7\">1.5<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et10\">10.3<\/td>\n<td class=\"et7\">0.85<\/td>\n<td class=\"et10\">2980<\/td>\n<td class=\"et10\">1350\u00d7980\u00d71320<\/td>\n<td class=\"et10\">820\/820<\/td>\n<td class=\"et10\">1750\u00d71350\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td class=\"et7\" style=\"height: 14.25pt;\" height=\"19\">1600<\/td>\n<td class=\"et7\">1.76<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et10\">12.5<\/td>\n<td class=\"et7\">0.85<\/td>\n<td class=\"et10\">3580<\/td>\n<td class=\"et10\">1400\u00d71120\u00d71400<\/td>\n<td class=\"et10\">1070\/1070<\/td>\n<td class=\"et10\">1800\u00d71400\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td class=\"et7\" style=\"height: 14.25pt;\" height=\"19\">2000<\/td>\n<td class=\"et7\">2.2<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et10\">15.5<\/td>\n<td class=\"et7\">0.7<\/td>\n<td class=\"et10\">4070<\/td>\n<td class=\"et10\">1440\u00d71120\u00d71520<\/td>\n<td class=\"et10\">1070\/1070<\/td>\n<td class=\"et10\">1850\u00d71450\u00d72200<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td class=\"et7\" style=\"height: 14.25pt;\" height=\"19\">2500<\/td>\n<td class=\"et7\">2.6<\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et8\"><\/td>\n<td class=\"et10\">18.4<\/td>\n<td class=\"et7\">0.7<\/td>\n<td class=\"et10\">4820<\/td>\n<td class=\"et10\">1500\u00d71120\u00d71640<\/td>\n<td class=\"et10\">1070\/1070<\/td>\n<td class=\"et10\">1900\u00d71500\u00d72200<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Le transformateur de puissance de type sec isol\u00e9 de classe H SG (B) pr\u00e9sente une forte r\u00e9sistance aux chocs thermiques, une capacit\u00e9 de surcharge \u00e9lev\u00e9e, un retardateur de flamme, une r\u00e9sistance \u00e9lev\u00e9e au feu, de faibles pertes, une faible d\u00e9charge partielle, un faible bruit, aucune production de gaz nocifs, aucune pollution environnementale, une insensibilit\u00e9 \u00e0 l'humidit\u00e9 et \u00e0 la poussi\u00e8re, une petite taille, aucune fissuration et un entretien facile.<\/p>","protected":false},"featured_media":1218,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[90,25],"product_tag":[],"class_list":["post-1217","product","type-product","status-publish","has-post-thumbnail","product_cat-dry-type-transformer","product_cat-transformers","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/product\/1217","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/comments?post=1217"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/media\/1218"}],"wp:attachment":[{"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/media?parent=1217"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/product_brand?post=1217"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/product_cat?post=1217"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/product_tag?post=1217"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}