{"id":1263,"date":"2026-04-07T13:57:36","date_gmt":"2026-04-07T05:57:36","guid":{"rendered":"https:\/\/wvefouvvpp.wpdns.site\/?post_type=product&#038;p=1263"},"modified":"2026-10-17T05:43:06","modified_gmt":"2026-10-17T05:43:06","slug":"kyn28a-12-metal-clad-withdrawable-ac-switchgear","status":"publish","type":"product","link":"https:\/\/lbajiele.com\/fr\/product\/kyn28a-12-metal-clad-withdrawable-ac-switchgear\/","title":{"rendered":"Appareillage sous enveloppe m\u00e9tallique d\u00e9brochable \u00e0 courant alternatif KYN28A-12"},"content":{"rendered":"<h2>Param\u00e8tres techniques<\/h2>\n<table style=\"border-collapse: collapse; width: 630.77pt;\" border=\"0\" width=\"841\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 13.50pt; width: 339.00pt;\" colspan=\"2\" width=\"452\" height=\"18\">Article<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">Unit\u00e9<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">Donn\u00e9es<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 13.50pt; width: 339.00pt;\" colspan=\"2\" width=\"452\" height=\"18\">Tension assign\u00e9e<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">kV<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">6, 7,2, 12<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 13.50pt; width: 339.00pt;\" colspan=\"2\" width=\"452\" height=\"18\">Fr\u00e9quence nominale<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">Hz<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">50<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 13.50pt; width: 339.00pt;\" colspan=\"2\" width=\"452\" height=\"18\">Courant assign\u00e9 du disjoncteur<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">A<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">630, 1250, 1600, 2000, 2500, 3150<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 13.50pt; width: 339.00pt;\" colspan=\"2\" width=\"452\" height=\"18\">Courant assign\u00e9 de l'appareillage<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">A<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">630, 1250, 1600, 2000, 2500, 3150<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 13.50pt; width: 339.00pt;\" colspan=\"2\" width=\"452\" height=\"18\">Courant de courte dur\u00e9e admissible<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">kA<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">20, 25, 31,5, 40<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 13.50pt; width: 339.00pt;\" colspan=\"2\" width=\"452\" height=\"18\">Courant de cr\u00eate admissible assign\u00e9<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">kA<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">50, 63, 80, 100<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 13.50pt; width: 339.00pt;\" colspan=\"2\" width=\"452\" height=\"18\">Courant de court-circuit assign\u00e9 de brisure<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">kA<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">20, 25, 31,5, 40<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 13.50pt; width: 339.00pt;\" colspan=\"2\" width=\"452\" height=\"18\">Pouvoir de fermeture en court-circuit assign\u00e9<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">kA<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">50, 63, 80, 100<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 27.00pt; width: 158.25pt;\" rowspan=\"2\" width=\"211\" height=\"36\">Niveau d'isolement assign\u00e9<br \/>\nFr\u00e9quence industrielle de 1 minute<br \/>\nTension de tenue<\/td>\n<td class=\"et2\" style=\"width: 180.75pt;\" width=\"241\">Entre p\u00f4les, P\u00f4le-terre<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">kV<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">24, 32, 42<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"width: 180.75pt;\" width=\"241\">\u00c0 travers les contacts ouverts<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">kV<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">24, 32, 42<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 27.00pt; width: 158.25pt;\" rowspan=\"2\" width=\"211\" height=\"36\">Choc de foudre<br \/>\nTension de tenue<br \/>\nPic<\/td>\n<td class=\"et2\" style=\"width: 180.75pt;\" width=\"241\">Entre p\u00f4les, P\u00f4le-terre<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">kV<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">40, 60, 75<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"width: 180.75pt;\" width=\"241\">\u00c0 travers les contacts ouverts<\/td>\n<td class=\"et2\" style=\"width: 58.50pt;\" width=\"78\">kV<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">46, 70, 85<\/td>\n<\/tr>\n<tr style=\"height: 67.50pt;\">\n<td class=\"et2\" style=\"height: 67.50pt; width: 397.50pt;\" colspan=\"3\" width=\"530\" height=\"90\">Degr\u00e9 de protection<\/td>\n<td class=\"et2\" style=\"width: 233.25pt;\" width=\"311\">L'enveloppe est IP4X, et lorsque les portes du compartiment et du local du disjoncteur sont ouvertes, elle est IP2X<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Vid\u00e9o<\/h2>\n<p><iframe loading=\"lazy\" title=\"KYN28A-12 12kV High Voltage Switchgear | Medium Voltage Switchgear for Power Distribution\" width=\"1600\" height=\"900\" src=\"https:\/\/www.youtube.com\/embed\/HROfEp6J0vQ?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/p>","protected":false},"excerpt":{"rendered":"<p>L'appareillage de commutation blind\u00e9 et d\u00e9brochable \u00e0 courant alternatif d'int\u00e9rieur KYN28A-12(Z) est con\u00e7u pour les syst\u00e8mes de distribution d'\u00e9lectricit\u00e9 \u00e0 courant alternatif triphas\u00e9 de 50 Hz et est utilis\u00e9 pour la r\u00e9ception et la distribution de l'\u00e9nergie \u00e9lectrique, ainsi que pour le contr\u00f4le, la protection et la surveillance des circuits \u00e9lectriques.<\/p>","protected":false},"featured_media":4327,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[27],"product_tag":[],"class_list":["post-1263","product","type-product","status-publish","has-post-thumbnail","product_cat-medium-voltage-switchgear","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/product\/1263","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/comments?post=1263"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/media\/4327"}],"wp:attachment":[{"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/media?parent=1263"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/product_brand?post=1263"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/product_cat?post=1263"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/lbajiele.com\/fr\/wp-json\/wp\/v2\/product_tag?post=1263"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}