Transformator terendam minyak S□-50~40000/35 berlaku untuk sistem tenaga listrik dengan AC 50 Hz dan voltase pengoperasian terukur 35 kV, yang berfungsi sebagai transformator untuk gardu induk kecil dan menengah.

35 kV oil-immersed power transformers in the published S11 schedule cover three-phase ratings from 50 kVA to 40,000 kVA. The tables below separate the 50–630 kVA configurations from the 800–40,000 kVA configurations. They show reference voltage combinations, vector groups, no-load and load losses, no-load current and short-circuit impedance. Use the exact project model and approved manufacturer drawing to confirm the final values before procurement.

How to Read the 35 kV Transformer Tables

The smaller 50–630 kVA group lists a 35 kV high-voltage winding with a ±5% tap range, a 0.4 kV low-voltage winding and a Yyn0 vector group. The larger models list different secondary voltage options and Yd11; some models also list a 38.5 kV high-voltage option. These are distinct configurations, not interchangeable settings on one unit. Confirm voltage, frequency, tap arrangement and vector group against the approved single-line diagram.

The first table expresses loss figures in watts (W). The second table expresses its loss figures in kilowatts (kW): for example, 1.23 and 9.9 for the 800 kVA model. The former page labeled both tables in W, which made the larger-model values misleading. The numerical values below are preserved from the published schedule; request the signed technical data sheet for contractual or efficiency calculations.

What to Confirm Before Ordering

Keputusan Project information to provide What the final data sheet should confirm
Tugas listrik Rated capacity, maximum demand, primary and secondary voltage, phase, frequency Selected model, winding ratings and tap range
Network connection Single-line diagram, neutral and earthing arrangement, upstream protection Vector group, terminal arrangement and impedance
Losses and performance Required efficiency evaluation and operating load profile Guaranteed no-load and load loss units, reference temperature and test method
Site conditions Indoor or outdoor location, ambient temperature, altitude and available space Cooling method, enclosure or tank arrangement, dimensions and mass
Acceptance Applicable standards, required tests, certificates and delivery documents Approved drawings, routine test report and final nameplate
Quotation checklist for a project-specific 35 kV oil-immersed transformer. The product table does not replace the final approved data sheet.

For replacement work, include photographs of the existing transformer nameplate, the oil containment and foundation area, bushing positions and cable or busbar connections. These details can determine whether a nominally similar kVA model actually fits. For new substations, confirm the transformer interface with the high-voltage switchgear and low-voltage distribution equipment before approving layout drawings.

Read our transformer sizes guide for capacity ranges and the panduan ukuran trafo for load calculations. Send the project data through the contact page to request a matching technical schedule.

Download a Project RFQ Worksheet

For a structured inquiry, download the 35 kV oil-immersed transformer project specification and RFQ worksheet (PDF). It separates buyer requirements from supplier confirmations and is not a certified, model-specific datasheet.

50–630 kVA Reference Parameters

Model Dinilai
Kapasitas
(kVA)
Tegangan Pengenal (kV) Vektor
Grup
Rugi(W) Tanpa Beban
Arus (%)
Pendek
Sirkuit
Impedansi (%)
Tegangan Tinggi (kV) Tegangan Rendah (kV) Tanpa Beban
Kehilangan
Muat
Kehilangan
S11-50/35 50 35±5% 0.4 Yyn0 210 1210 1.8 6.5
S11-100/35 100 290 2020 1.62
S11-125/35 125 340 2380 1.56
S11-160/35 160 360 2830 1.48
S11-200/35 200 430 3300 1.39
S11-250/35 250 510 3960 1.26
S11-315/35 315 610 4760 1.26
S11-400/35 400 733 5760 1.16
S11-500/35 500 860 6900 1.16
S11-630/35 630 1040 8280 1.1

800–40,000 kVA Reference Parameters

Model Dinilai
Kapasitas
(kVA)
Tegangan Pengenal (kV) Vektor
Grup
Rugi-rugi (kW) Tanpa Beban
Arus (%)
Pendek
Sirkuit
Impedansi (%)
Tegangan Tinggi (kV) Tegangan Rendah (kV) Tanpa Beban
Kehilangan
Muat
Kehilangan
S11-800/35 800 35±5% 10.5
6.3
3.15
Yd11 1.23 9.9 0.9 6.5
S11-1000/35 1000 1.44 12.1 0.9 6.5
S11-1250/35 1250 1.76 14.6 0.81 6.5
S11-1600/35 1600 2.12 17.5 0.76 6.5
S11-2000/35 2000 2.72 17.8 0.67 6.5
S11-2500/35 2500 3.2 20.7 0.67 6.5
S11-3150/35 3150 35±5%
38,5±5%
3.8 24.3 0.63 7.0
S11-4000/35 4000 4.52 28.8 0.63 7.0
S11-5000/35 5000 5.4 33 0.54 7.0
S11-6300/35 6300 35±2×2,5%
38,5±2×2,51 TP3T
11
10.5
6.6
6.3
3.3
3.15
Yd11 6.56 36.9 0.54 7.5
S11-8000/35 8000 9.0 40.5 0.49 7.5
S11-10000/35 10000 10.88 47.7 0.49 7.5
S11-12500/35 12500 12.6 56.7 0.45 8
S11-16000/35 16000 15.2 69.3 0.45 8
S11-20000/35 20000 18 83.7 0.45 8
S11-25000/35 25000 21.28 99 0.36 8
S11-31500/35 31500 25.28 118.8 0.36 8
S11-40000/35 40000 28.8 155.25 0.48 8

All listed values are reference data for model selection. Final dimensions, weights and electrical values must follow the approved project drawings and manufacturer data sheet.

Pertanyaan yang Sering Diajukan

Jenis trafo apa saja yang Anda produksi?

LBAJI memproduksi berbagai trafo, termasuk:

  • Trafo Distribusi Tenga Minyak
  • Trafo Kering
  • Trafo Resin Cor
  • Transformator Daya
  • Transformator Peningkatan Tenaga Surya

Transformator kami banyak digunakan di:

  • Pabrik industri
  • Ladang surya
  • Bangunan komersial
  • Proyek pertambangan
  • Proyek infrastruktur
Berapa tingkat tegangan yang dapat didukung oleh trafo Anda?

Transformator kami dapat dirancang sesuai dengan berbagai persyaratan proyek.

Kisaran tegangan tipikal meliputi:

  • Tegangan Rendah: 0,4kV
  • Tegangan Menengah: 6kV, 10kV, 11kV, 20kV, 22kV, 33kV
  • Tingkat tegangan yang lebih tinggi tersedia atas permintaan

Peringkat transformator juga dapat disesuaikan menurut persyaratan kapasitas proyek.

Apa perbedaan antara transformator rendam minyak dan transformator tipe kering?

Transformator Rendam Minyak

Kelebihan:

  • Rentang kapasitas yang lebih tinggi
  • Performa pendinginan yang lebih baik
  • Cocok untuk aplikasi luar ruangan
  • Hemat biaya untuk proyek besar

Aplikasi:

  • Jaringan listrik
  • Fasilitas industri
  • Ladang surya

Trafo Kering

Kelebihan:

  • Tahan api
  • Ramah lingkungan
  • Perawatan rendah
  • Cocok untuk pemasangan di dalam ruangan

Aplikasi:

  • Bangunan
  • Rumah sakit
  • Pusat data
  • Fasilitas komersial
Transformator Anda memenuhi standar apa?

Produk kami dapat dibuat sesuai dengan standar internasional termasuk:

  • Standar IEC
  • Standar IEEE
  • Standar GB

Laporan pengujian dan dokumen teknis dapat disediakan sesuai dengan persyaratan proyek.