{"id":1201,"date":"2026-04-06T13:59:00","date_gmt":"2026-04-06T05:59:00","guid":{"rendered":"https:\/\/wvefouvvpp.wpdns.site\/?post_type=product&#038;p=1201"},"modified":"2026-09-28T07:53:44","modified_gmt":"2026-09-28T07:53:44","slug":"35kv-new-energy-box-type-chinese-style-substation","status":"publish","type":"product","link":"https:\/\/lbajiele.com\/id\/product\/35kv-new-energy-box-type-chinese-style-substation\/","title":{"rendered":"Gardu Trafo Tipe-Kotak Energi Baru 35KV (Gaya-Tiongkok)"},"content":{"rendered":"<h2><strong><b>Ikhtisar<\/b><\/strong><\/h2>\n<p>Gardu induk prarakit kompak 35kV, yang umumnya dikenal sebagai gardu tipe kotak Tiongkok, adalah jenis gardu tipe kotak baru, dan produknya banyak digunakan di ladang angin dan pembangkit listrik fotovoltaik. Gardu ini terutama terdiri dari bodi transformator, bagian kelistrikan tegangan tinggi, bagian kelistrikan tegangan rendah, kotak, dll. Transformator tersebut adalah transformator daya pengatur tegangan non-eksitasi berpendingin oli tiga fase belitan ganda; bagian kelistrikan tegangan tinggi dari Transformator Kotak Huashi terutama terdiri dari pemutus sirkuit tegangan tinggi 35kV, sakelar pemisah 35kV, trafo arus 35kV, trafo tegangan 35kV, penangkal petir 35kV, layar langsung 35kV, dll., sedangkan bagian kelistrikan tegangan rendah dari Transformator Kotak Huashi terutama terdiri dari pemutus sirkuit rangka tegangan rendah, sistem penggunaan sendiri (transformator penggunaan sendiri, sakelar pengumpan, dll.), pelindung lonjakan arus, dll.<\/p>\n<h2><strong><b>Arti Model<\/b><\/strong><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1203\" src=\"https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/1-4.webp\" alt=\"\" width=\"1200\" height=\"202\" srcset=\"https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/1-4.webp 1200w, https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/1-4-300x51.webp 300w, https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/1-4-1024x172.webp 1024w, https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/1-4-768x129.webp 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/p>\n<h2><strong><b>Fitur produk<\/b><\/strong><\/h2>\n<ul>\n<li>Struktur yang padat, ukuran kecil, pemasangan yang mudah dan fleksibel;<\/li>\n<li>Berisolasi penuh, struktur tertutup penuh, aman dan andal, bebas perawatan, dan melindungi keselamatan pribadi dengan andal;<\/li>\n<li>Sisi tegangan tinggi dilindungi oleh sekering ganda. Sekering tancap adalah sekering sensitif ganda (suhu, arus), dan sekering cadangan adalah sekering pembatas arus, yang mengurangi biaya operasional;<\/li>\n<li>Saluran masuk tegangan tinggi mengadopsi struktur konektor kabel, yang sepenuhnya terisolasi, aman dan andal, serta mudah dioperasikan;<\/li>\n<li>Ini dapat digunakan untuk jaringan cincin maupun terminal. Konversinya sangat praktis dan meningkatkan keandalan catu daya.<\/li>\n<li>Transformator ini memiliki struktur tiga fasa tiga kolom atau tiga fasa lima kolom. Inti besi mengadopsi proses sambungan bertingkat atau proses inti gulg, yang memiliki kebisingan rendah, rugi-rugi rendah, serta ketahanan yang kuat terhadap hubung singkat dan kelebihan beban.<\/li>\n<li>Menggunakan proses khusus pengeringan vakum dan pelumasan vakum, perusahaan kami akan memperluas proses ini yang digunakan pada produk 110kV ke produk 10kV, memberikan jaminan kuat untuk meningkatkan kualitas produk.<\/li>\n<li>Kotak tersebut dapat dirancang dengan perawatan anti-korosi dan pengecatan khusus sesuai dengan persyaratan lingkungan operasional. Kotak ini memiliki fungsi \u201ctiga pencegahan\u201d, yaitu anti-kondensasi, anti-kabut garam, dan anti-jamur, serta dapat memenuhi persyaratan anti-korosi di lingkungan bersuhu tinggi dan kelembapan tinggi.<\/li>\n<\/ul>\n<h2><strong><b>Standar &amp; parameter terkait<\/b><\/strong><\/h2>\n<ul>\n<li>GB 1094.1-2013 Transformator daya Bagian 1: Prinsip umum<\/li>\n<li>GB\/T 15164-2022 Panduan Beban untuk Transformator Daya Rendam Minyak<\/li>\n<li>Peraturan Operasi Transformator Daya DL\/T 572-2010<\/li>\n<li>Seri standar internasional IEC 60076 untuk transformator daya<\/li>\n<li>Standar Minyak Transformator GB 2536-2011<\/li>\n<\/ul>\n<h2><strong><b>Persyaratan Teknis untuk Gardu Induk di China<\/b><\/strong><\/h2>\n<p>Trafo kotak Huashi terdiri dari tiga bagian: ruang tegangan tinggi, transformator, dan ruang tegangan rendah. Setiap ruang dipisahkan menjadi kompartemen-kompartemen independen oleh sekat, dan sebuah manhole disediakan di dalam kotak untuk memudahkan pemasangan dan pemeliharaan. Tata letak internalnya diatur sesuai dengan persyaratan gambar desain standar. Trafo kotak ini mengadopsi metode pendinginan alami, dan suhu ruang tekanan rendah dikendalikan di bawah 60 \u2103 melalui perangkat pendingin di dalam kabinet untuk memastikan lingkungan pengoperasian yang baik bagi peralatan sekunder. Kabinet komunikasi perlu dipasang di atas kabinet trafo (memasang sakelar, kotak serat optik, dan peralatan lainnya), kabinet baterai UPS beroperasi di bawah kelebihan beban jangka panjang yang terus menerus pada 1,1 kali (suhu oli tidak boleh melebihi 85\u2103 di lingkungan proyek), 1,2 kali (suhu oli tidak boleh melebihi 85 \u2103 di lingkungan proyek, dan kenaikan suhu di bawah operasi kelebihan beban jangka pendek pada 1,5 kali harus mematuhi ketentuan \u201dPeralatan Umum untuk Proyek Transmisi dan Transformasi Daya State Grid Corporation of China\" (Spesifikasi Khas untuk Gardu Induk dan Distribusi Daya 66kV ke Bawah) serta nilai-nilai yang relevan pada Tabel 3-2.<\/p>\n<p>Tindakan dehumidifikasi, pencegahan ledakan, dan pencegahan kondensasi harus dilakukan di dalam transformator kotak. Lubang kabel di ruang tekanan tinggi dan rendah harus disegel dengan bahan penyegel fleksibel polimer TS-68 berdasarkan penyegelan dengan lumpur tahan api. Pasang strip penyegel pada pintu kabinet transformator kotak. Strip penyegel terbuat dari karet etilena propilena diena monomer, yang memiliki ketahanan panas, ketahanan cuaca, ketahanan ozon, ketahanan korosi, dan ketahanan penuaan yang baik. Bagian-bagian bertegangan seperti ujung kabel tegangan tinggi, busbar, dan terminal terisolasi penuh dengan bahan isolasi karet silikon tahan api dan konduktif termal TS-10. Setelah perlakuan isolasi, bagian bertegangan tinggi 35kV harus mampu menahan tegangan tahan sebesar 40,5kV selama 1 menit; Setelah perlakuan isolasi, busbar tegangan rendah harus mampu menahan tegangan tahan sebesar 2,5kV selama 1 menit. Botol porselen bushing tegangan tinggi, batang isolasi, insulator, dan perangkat isolasi lainnya dilapisi dengan cat anti-polusi flash pembersihan mandiri tinggi SRTV, dengan ketebalan lapisan 0,4\u00b10,1mm. Penjual bertanggung jawab untuk memodifikasi kipas pendingin tambahan dan mengadopsi ventilasi sirkulasi eksternal untuk pendinginan. (Hapus) Masa pakai desain transformator kotak tidak boleh kurang dari 30 tahun. Setiap kompartemen transformator kotak harus dilengkapi dengan konfigurasi kombinasi pemanas bertenaga normal berdaya rendah dan dehumidifier. Lubang ventilasi harus diatur secara wajar sesuai dengan volume kabinet. Sinyal suhu dan kelembapan transformator kotak harus memiliki fungsi transmisi jarak jauh dan diunggah ke transformator kotak melalui antarmuka komunikasi. Perangkat pengukuran dan kontrol.<\/p>\n<h2><strong><b>Dimensi tampilan dan pemasangan<\/b><\/strong><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1204\" src=\"https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/Appearance-and-installation-dimensions.webp\" alt=\"\" width=\"1200\" height=\"816\" srcset=\"https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/Appearance-and-installation-dimensions.webp 1200w, https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/Appearance-and-installation-dimensions-300x204.webp 300w, https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/Appearance-and-installation-dimensions-1024x696.webp 1024w, https:\/\/lbajiele.com\/wp-content\/uploads\/2026\/04\/Appearance-and-installation-dimensions-768x522.webp 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/p>\n<h2><strong><b>Parameter Teknis<\/b><\/strong><\/h2>\n<table style=\"height: 486px;\" width=\"756\">\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"144\">Barang<\/td>\n<td width=\"72\">unit<\/td>\n<td colspan=\"2\" width=\"144\">Sakelar Tegangan Tinggi<\/td>\n<td colspan=\"2\" width=\"144\">Transformator<\/td>\n<td width=\"143\">Peralatan Tegangan Rendah<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Tegangan Pengenal<\/td>\n<td>kV<\/td>\n<td>12<\/td>\n<td>40.5<\/td>\n<td>10.5\/0.8<\/td>\n<td>35\/0.8<\/td>\n<td>0.8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Kapasitas Terukur<\/td>\n<td>kVA<\/td>\n<td colspan=\"2\"><\/td>\n<td colspan=\"2\">1000-3300<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Frekuensi Nominal<\/td>\n<td>HZ<\/td>\n<td colspan=\"2\">50<\/td>\n<td colspan=\"2\">50<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Arus Nominal<\/td>\n<td>A<\/td>\n<td>200<\/td>\n<td>63<\/td>\n<td colspan=\"2\"><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"72\">Frekuensi Daya 1 Menit<br \/>\nTegangan tembus<\/td>\n<td width=\"72\">Interfase<br \/>\nDan Tanah<\/td>\n<td>kV<\/td>\n<td>42<\/td>\n<td>95<\/td>\n<td>35<\/td>\n<td>85<\/td>\n<td rowspan=\"2\">5<\/td>\n<\/tr>\n<tr>\n<td width=\"72\">Isolasi<br \/>\nFraktur<\/td>\n<td>kV<\/td>\n<td>48<\/td>\n<td>110<\/td>\n<td colspan=\"2\"><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"72\">Impuls Kilat<br \/>\nTegangan tembus<\/td>\n<td>Antarfasa dan Tanah<\/td>\n<td>kV<\/td>\n<td>75<\/td>\n<td>185<\/td>\n<td>75<\/td>\n<td>220<\/td>\n<td rowspan=\"2\">12<\/td>\n<\/tr>\n<tr>\n<td>Fraktur Isolasi<\/td>\n<td>kV<\/td>\n<td>85<\/td>\n<td>215<\/td>\n<td colspan=\"2\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Arus Hubung Singkat Putus Pengenal (Nilai Efektif)<\/td>\n<td>Kereta Api<\/td>\n<td><\/td>\n<td>31.5<\/td>\n<td colspan=\"2\"><\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Arus Tahan Waktu Singkat Pengenal (Nilai Efektif)<\/td>\n<td>Kereta Api<\/td>\n<td>20(4S)<\/td>\n<td>20(4S)<\/td>\n<td colspan=\"2\"><\/td>\n<td>40(1S)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Arus Hubung Singkat Penutupan Pengenal (Puncak)<\/td>\n<td>Kereta Api<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td colspan=\"2\"><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Arus Tahan Puncak Pengenal<\/td>\n<td>kak<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td colspan=\"2\"><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Tingkat Perlindungan<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td>IP33<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Tingkat Kebisingan<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td>\u226455dB<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong><b>Tabel Pemilihan Komponen<\/b><\/strong><\/h2>\n<table style=\"border-collapse: collapse; width: 520.52pt;\" border=\"0\" width=\"694\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" style=\"height: 27.00pt; width: 63.75pt;\" rowspan=\"2\" width=\"85\" height=\"36\">Kapasitas Terukur<br \/>\n(KVA)<\/td>\n<td class=\"et3\" style=\"width: 85.50pt;\" colspan=\"2\" width=\"114\">Saklar Tegangan Tinggi<\/td>\n<td class=\"et3\" style=\"width: 118.50pt;\" colspan=\"2\" width=\"158\">Sekring Tegangan Tinggi<\/td>\n<td class=\"et3\" style=\"width: 123.00pt;\" colspan=\"2\" width=\"164\">Penyerap Petir Tegangan Tinggi<\/td>\n<td class=\"et2\" style=\"width: 63.00pt;\" rowspan=\"2\" width=\"84\">Tegangan Rendah<br \/>\nAlihkan<\/td>\n<td class=\"et2\" style=\"width: 66.75pt;\" rowspan=\"2\" width=\"89\">Pendukung<br \/>\nTransformator<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et4\">12<\/td>\n<td class=\"et4\">40.5<\/td>\n<td class=\"et4\">12<\/td>\n<td class=\"et4\">40.5<\/td>\n<td class=\"et4\">12<\/td>\n<td class=\"et4\">40.5<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et4\" style=\"height: 13.50pt;\" height=\"18\">1000<\/td>\n<td class=\"et2\" style=\"width: 45.00pt;\" rowspan=\"6\" width=\"60\">FZRN25-12<br \/>\nVTK-12<\/td>\n<td class=\"et3\" rowspan=\"6\">FT16-40.5<\/td>\n<td class=\"et3\">XRNT-12\/100<\/td>\n<td class=\"et3\">XRNT-40.5\/30<\/td>\n<td class=\"et3\" rowspan=\"6\">HY-5WZ-17\/45<\/td>\n<td class=\"et3\" rowspan=\"6\">HY-5WZ-51\/134<\/td>\n<td class=\"et2\" style=\"width: 63.00pt;\" rowspan=\"6\" width=\"84\">RDW1<br \/>\nPemutus Arus<br \/>\nKFW2<br \/>\nPemutus Arus<\/td>\n<td class=\"et2\" style=\"width: 66.75pt;\" rowspan=\"6\" width=\"89\">Kapasitas bisa<br \/>\nbertekad untuk<br \/>\npermintaan<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et4\" style=\"height: 13.50pt;\" height=\"18\">1600<\/td>\n<td class=\"et3\">XRNT-12\/160<\/td>\n<td class=\"et3\">XRNT-40.5\/30<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et4\" style=\"height: 13.50pt;\" height=\"18\">2000<\/td>\n<td class=\"et3\">XRNT-12\/200<\/td>\n<td class=\"et3\">XRNT-40.5\/60<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et4\" style=\"height: 13.50pt;\" height=\"18\">2500<\/td>\n<td class=\"et3\"><\/td>\n<td class=\"et3\">XRNT-40.5\/80<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et4\" style=\"height: 13.50pt;\" height=\"18\">3150<\/td>\n<td class=\"et3\"><\/td>\n<td class=\"et3\">XRNT-40.5\/100A<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et4\" style=\"height: 13.50pt;\" height=\"18\">3300<\/td>\n<td class=\"et3\"><\/td>\n<td class=\"et3\">XRNT-40.5\/100A<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Substation pra-pasang kompak 35kV adalah jenis gardu tipe kotak baru, dan produknya banyak digunakan di ladang angin dan pembangkit listrik fotovoltaik. Ini terutama terdiri dari bodi transformator, bagian listrik tegangan tinggi, bagian listrik tegangan rendah, kotak, dll.<\/p>","protected":false},"featured_media":1202,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[28],"product_tag":[],"class_list":["post-1201","product","type-product","status-publish","has-post-thumbnail","product_cat-prefabricated-distribution-substation","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/lbajiele.com\/id\/wp-json\/wp\/v2\/product\/1201","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lbajiele.com\/id\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/lbajiele.com\/id\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/lbajiele.com\/id\/wp-json\/wp\/v2\/comments?post=1201"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lbajiele.com\/id\/wp-json\/wp\/v2\/media\/1202"}],"wp:attachment":[{"href":"https:\/\/lbajiele.com\/id\/wp-json\/wp\/v2\/media?parent=1201"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/lbajiele.com\/id\/wp-json\/wp\/v2\/product_brand?post=1201"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/lbajiele.com\/id\/wp-json\/wp\/v2\/product_cat?post=1201"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/lbajiele.com\/id\/wp-json\/wp\/v2\/product_tag?post=1201"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}