{"id":1182,"date":"2026-04-06T13:14:34","date_gmt":"2026-04-06T05:14:34","guid":{"rendered":"https:\/\/wvefouvvpp.wpdns.site\/?post_type=product&#038;p=1182"},"modified":"2026-08-27T05:59:56","modified_gmt":"2026-08-27T05:59:56","slug":"s-m-35kv-oil-immersed-power-transformer","status":"publish","type":"product","link":"https:\/\/lbajiele.com\/vi\/san-pham\/s-m-35kv-oil-immersed-power-transformer\/","title":{"rendered":"M\u00e1y bi\u1ebfn \u00e1p l\u1ef1c ng\u00e2m d\u1ea7u 35kV S\u25a1 \u2013 M"},"content":{"rendered":"<h2>Technical Parameters Of 35kV Three-phase Power Transformer<\/h2>\n<table width=\"730\">\n<tbody>\n<tr>\n<td rowspan=\"2\" width=\"105\">Model<\/td>\n<td rowspan=\"2\" width=\"72\">Rated<br \/>\nC\u00f4ng su\u1ea5t<br \/>\n(kVA)<\/td>\n<td colspan=\"2\" width=\"209\">Rated Voltage(kV)<\/td>\n<td rowspan=\"2\" width=\"53\">Vector<br \/>\nGroup<\/td>\n<td colspan=\"2\" width=\"104\">Loss(W)<\/td>\n<td rowspan=\"2\" width=\"85\">No-Load<br \/>\nCurrent(%)<\/td>\n<td rowspan=\"2\" width=\"102\">Short<br \/>\nCircuit<br \/>\nImpedance(%)<\/td>\n<\/tr>\n<tr>\n<td width=\"116\">High Voltage(kV)<\/td>\n<td width=\"93\">Low Voltage(kV)<\/td>\n<td width=\"61\">No-Load<br \/>\nLoss<\/td>\n<td width=\"43\">Load<br \/>\nLoss<\/td>\n<\/tr>\n<tr>\n<td width=\"105\">S11-50\/35<\/td>\n<td width=\"72\">50<\/td>\n<td rowspan=\"10\" width=\"116\">35\u00b15%<\/td>\n<td rowspan=\"10\" width=\"93\">0.4<\/td>\n<td rowspan=\"10\" width=\"53\">Yyn0<\/td>\n<td width=\"61\">210<\/td>\n<td width=\"43\">1210<\/td>\n<td width=\"85\">1.8<\/td>\n<td rowspan=\"10\">6.5<\/td>\n<\/tr>\n<tr>\n<td width=\"105\">S11-100\/35<\/td>\n<td width=\"72\">100<\/td>\n<td width=\"61\">290<\/td>\n<td width=\"43\">2020<\/td>\n<td width=\"85\">1.62<\/td>\n<\/tr>\n<tr>\n<td width=\"105\">S11-125\/35<\/td>\n<td width=\"72\">125<\/td>\n<td width=\"61\">340<\/td>\n<td width=\"43\">2380<\/td>\n<td width=\"85\">1.56<\/td>\n<\/tr>\n<tr>\n<td width=\"105\">S11-160\/35<\/td>\n<td width=\"72\">160<\/td>\n<td width=\"61\">360<\/td>\n<td width=\"43\">2830<\/td>\n<td width=\"85\">1.48<\/td>\n<\/tr>\n<tr>\n<td width=\"105\">S11-200\/35<\/td>\n<td width=\"72\">200<\/td>\n<td width=\"61\">430<\/td>\n<td width=\"43\">3300<\/td>\n<td width=\"85\">1.39<\/td>\n<\/tr>\n<tr>\n<td width=\"105\">S11-250\/35<\/td>\n<td width=\"72\">250<\/td>\n<td width=\"61\">510<\/td>\n<td width=\"43\">3960<\/td>\n<td width=\"85\">1.26<\/td>\n<\/tr>\n<tr>\n<td width=\"105\">S11-315\/35<\/td>\n<td width=\"72\">315<\/td>\n<td width=\"61\">610<\/td>\n<td width=\"43\">4760<\/td>\n<td width=\"85\">1.26<\/td>\n<\/tr>\n<tr>\n<td width=\"105\">S11-400\/35<\/td>\n<td width=\"72\">400<\/td>\n<td width=\"61\">733<\/td>\n<td width=\"43\">5760<\/td>\n<td width=\"85\">1.16<\/td>\n<\/tr>\n<tr>\n<td width=\"105\">S11-500\/35<\/td>\n<td width=\"72\">500<\/td>\n<td width=\"61\">860<\/td>\n<td width=\"43\">6900<\/td>\n<td width=\"85\">1.16<\/td>\n<\/tr>\n<tr>\n<td width=\"105\">S11-630\/35<\/td>\n<td width=\"72\">630<\/td>\n<td width=\"61\">1040<\/td>\n<td width=\"43\">8280<\/td>\n<td width=\"85\">1.1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Note: All listed overall dimensions and weights are for reference only for design &amp; type selection purposes. Final physical dimensions and weights shall prevail as per our official product drawings.<\/p>\n<h2>Technical Parameters Of 35kV Three-phase Power Transformer<\/h2>\n<table width=\"757\">\n<tbody>\n<tr>\n<td rowspan=\"2\" width=\"132\">Model<\/td>\n<td rowspan=\"2\" width=\"72\">Rated<br \/>\nC\u00f4ng su\u1ea5t<br \/>\n(kVA)<\/td>\n<td colspan=\"2\" width=\"209\">Rated Voltage(kV)<\/td>\n<td rowspan=\"2\" width=\"53\">Vector<br \/>\nGroup<\/td>\n<td colspan=\"2\" width=\"104\">Loss(W)<\/td>\n<td rowspan=\"2\" width=\"85\">No-Load<br \/>\nCurrent(%)<\/td>\n<td rowspan=\"2\" width=\"102\">Short<br \/>\nCircuit<br \/>\nImpedance(%)<\/td>\n<\/tr>\n<tr>\n<td width=\"116\">High Voltage(kV)<\/td>\n<td width=\"93\">Low Voltage(kV)<\/td>\n<td width=\"61\">No-Load<br \/>\nLoss<\/td>\n<td width=\"43\">Load<br \/>\nLoss<\/td>\n<\/tr>\n<tr>\n<td width=\"132\">S11-800\/35<\/td>\n<td width=\"72\">800<\/td>\n<td rowspan=\"6\" width=\"116\">35\u00b15%<\/td>\n<td rowspan=\"9\" width=\"93\">10.5<br \/>\n6.3<br \/>\n3.15<\/td>\n<td rowspan=\"9\" width=\"53\">Yd11<\/td>\n<td width=\"61\">1.23<\/td>\n<td width=\"43\">9.9<\/td>\n<td width=\"85\">0.9<\/td>\n<td width=\"102\">6.5<\/td>\n<\/tr>\n<tr>\n<td width=\"132\">S11-1000\/35<\/td>\n<td width=\"72\">1000<\/td>\n<td width=\"61\">1.44<\/td>\n<td width=\"43\">12.1<\/td>\n<td width=\"85\">0.9<\/td>\n<td width=\"102\">6.5<\/td>\n<\/tr>\n<tr>\n<td width=\"132\">S11-1250\/35<\/td>\n<td width=\"72\">1250<\/td>\n<td width=\"61\">1.76<\/td>\n<td width=\"43\">14.6<\/td>\n<td width=\"85\">0.81<\/td>\n<td width=\"102\">6.5<\/td>\n<\/tr>\n<tr>\n<td width=\"132\">S11-1600\/35<\/td>\n<td width=\"72\">1600<\/td>\n<td width=\"61\">2.12<\/td>\n<td width=\"43\">17.5<\/td>\n<td width=\"85\">0.76<\/td>\n<td width=\"102\">6.5<\/td>\n<\/tr>\n<tr>\n<td width=\"132\">S11-2000\/35<\/td>\n<td width=\"72\">2000<\/td>\n<td width=\"61\">2.72<\/td>\n<td width=\"43\">17.8<\/td>\n<td width=\"85\">0.67<\/td>\n<td width=\"102\">6.5<\/td>\n<\/tr>\n<tr>\n<td width=\"132\">S11-2500\/35<\/td>\n<td width=\"72\">2500<\/td>\n<td width=\"61\">3.2<\/td>\n<td width=\"43\">20.7<\/td>\n<td width=\"85\">0.67<\/td>\n<td width=\"102\">6.5<\/td>\n<\/tr>\n<tr>\n<td width=\"132\">S11-3150\/35<\/td>\n<td width=\"72\">3150<\/td>\n<td rowspan=\"3\" width=\"116\">35\u00b15%<br \/>\n38.5\u00b15%<\/td>\n<td width=\"61\">3.8<\/td>\n<td width=\"43\">24.3<\/td>\n<td width=\"85\">0.63<\/td>\n<td width=\"102\">7.0<\/td>\n<\/tr>\n<tr>\n<td width=\"132\">S11-4000\/35<\/td>\n<td width=\"72\">4000<\/td>\n<td width=\"61\">4.52<\/td>\n<td width=\"43\">28.8<\/td>\n<td width=\"85\">0.63<\/td>\n<td width=\"102\">7.0<\/td>\n<\/tr>\n<tr>\n<td width=\"132\">S11-5000\/35<\/td>\n<td width=\"72\">5000<\/td>\n<td width=\"61\">5.4<\/td>\n<td width=\"43\">33<\/td>\n<td width=\"85\">0.54<\/td>\n<td width=\"102\">7.0<\/td>\n<\/tr>\n<tr>\n<td width=\"132\">S11-6300\/35<\/td>\n<td width=\"72\">6300<\/td>\n<td rowspan=\"9\" width=\"116\">35\u00b12\u00d72.5%<br \/>\n38.5\u00b12\u00d72.5%<\/td>\n<td rowspan=\"9\" width=\"93\">11<br \/>\n10.5<br \/>\n6.6<br \/>\n6.3<br \/>\n3.3<br \/>\n3.15<\/td>\n<td rowspan=\"9\" width=\"53\">Yd11<\/td>\n<td width=\"61\">6.56<\/td>\n<td width=\"43\">36.9<\/td>\n<td width=\"85\">0.54<\/td>\n<td width=\"102\">7.5<\/td>\n<\/tr>\n<tr>\n<td width=\"132\">S11-8000\/35<\/td>\n<td width=\"72\">8000<\/td>\n<td width=\"61\">9.0<\/td>\n<td width=\"43\">40.5<\/td>\n<td width=\"85\">0.49<\/td>\n<td width=\"102\">7.5<\/td>\n<\/tr>\n<tr>\n<td width=\"132\">S11-10000\/35<\/td>\n<td width=\"72\">10000<\/td>\n<td width=\"61\">10.88<\/td>\n<td width=\"43\">47.7<\/td>\n<td width=\"85\">0.49<\/td>\n<td width=\"102\">7.5<\/td>\n<\/tr>\n<tr>\n<td width=\"132\">S11-12500\/35<\/td>\n<td width=\"72\">12500<\/td>\n<td width=\"61\">12.6<\/td>\n<td width=\"43\">56.7<\/td>\n<td width=\"85\">0.45<\/td>\n<td width=\"102\">8<\/td>\n<\/tr>\n<tr>\n<td width=\"132\">S11-16000\/35<\/td>\n<td width=\"72\">16000<\/td>\n<td width=\"61\">15.2<\/td>\n<td width=\"43\">69.3<\/td>\n<td width=\"85\">0.45<\/td>\n<td width=\"102\">8<\/td>\n<\/tr>\n<tr>\n<td width=\"132\">S11-20000\/35<\/td>\n<td width=\"72\">20000<\/td>\n<td width=\"61\">18<\/td>\n<td width=\"43\">83.7<\/td>\n<td width=\"85\">0.45<\/td>\n<td width=\"102\">8<\/td>\n<\/tr>\n<tr>\n<td width=\"132\">S11-25000\/35<\/td>\n<td width=\"72\">25000<\/td>\n<td width=\"61\">21.28<\/td>\n<td width=\"43\">99<\/td>\n<td width=\"85\">0.36<\/td>\n<td width=\"102\">8<\/td>\n<\/tr>\n<tr>\n<td width=\"132\">S11-31500\/35<\/td>\n<td width=\"72\">31500<\/td>\n<td width=\"61\">25.28<\/td>\n<td width=\"43\">118.8<\/td>\n<td width=\"85\">0.36<\/td>\n<td width=\"102\">8<\/td>\n<\/tr>\n<tr>\n<td width=\"132\">S11-40000\/35<\/td>\n<td width=\"72\">40000<\/td>\n<td width=\"61\">28.8<\/td>\n<td width=\"43\">155.25<\/td>\n<td width=\"85\">0.48<\/td>\n<td width=\"102\">8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Note: All listed overall dimensions and weights are for reference only for design &amp; type selection purposes. Final physical dimensions and weights shall prevail as per our official product drawings.<\/p>","protected":false},"excerpt":{"rendered":"<p>An S\u25a1-50~40000\/35 oil-immersed transformer is applicable to power systems with AC 50 Hz and rated operating voltage of 35 kV, serving as transformers for small and medium-sized substations.<\/p>","protected":false},"featured_media":1184,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[89,25],"product_tag":[],"class_list":["post-1182","product","type-product","status-publish","has-post-thumbnail","product_cat-oil-immersed-transformer","product_cat-transformer","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/lbajiele.com\/vi\/wp-json\/wp\/v2\/product\/1182","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lbajiele.com\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/lbajiele.com\/vi\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/lbajiele.com\/vi\/wp-json\/wp\/v2\/comments?post=1182"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lbajiele.com\/vi\/wp-json\/wp\/v2\/media\/1184"}],"wp:attachment":[{"href":"https:\/\/lbajiele.com\/vi\/wp-json\/wp\/v2\/media?parent=1182"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/lbajiele.com\/vi\/wp-json\/wp\/v2\/product_brand?post=1182"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/lbajiele.com\/vi\/wp-json\/wp\/v2\/product_cat?post=1182"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/lbajiele.com\/vi\/wp-json\/wp\/v2\/product_tag?post=1182"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}