1000V DC Combiner Box: Guide

A 1000V DC combiner box collects photovoltaic string circuits before an inverter or DC collection feeder. At this voltage class, insulation coordination, DC arc interruption, creepage, clearance, polarity and surge…

LBAJI electrical equipment illustration for 33kV GIS Switchgear

33kV GIS Switchgear: Guide

33kV GIS switchgear is a medium-voltage gas-insulated assembly for switching, protection, isolation and distribution at 33 kV. The primary conductors, busbars and switching devices are enclosed in grounded compartments…

LBAJI electrical equipment illustration for Complete Guide to Ring Main Units

Complete Guide to Ring Main Units

Ring main units (RMUs) in electrical distribution are compact medium-voltage assemblies used to switch, protect and sectionalize ring or radial feeders. An RMU normally combines load-break switches, an earth switch,…

LBAJI electrical equipment illustration for 120V AC Distribution Panel

120V AC Distribution Panel: Guide

A 120V AC distribution panel distributes single-phase branch circuits from a defined line-to-neutral or line-to-line source. The panel rating, feeder, neutral, grounding, breaker family, available fault current and enclosure must all be verified. “120 V” describes the nominal circuit voltage;…

LBAJI electrical equipment illustration for Switchgear Manufacturer East Coast

Switchgear Manufacturer East Coast: Cost and Procurement Guide

Medium-voltage switchgear controls and protects electrical distribution systems between low-voltage utilization and high-voltage transmission. It is used in utility substations, factories, data centers, mines, buildings and renewable-energy plants. This guide compares air- and gas-insulated, metal-clad and ring-main designs and explains…

LBAJI electrical equipment illustration for Power Factor Of Motor

Power Factor Of Motor: Guide

The power factor of a motor describes how effectively the motor converts apparent electrical power into real mechanical output. Induction motors normally have lagging power factor because their magnetic field requires reactive current. The value changes with load, voltage, speed,…

How To Know If Power Factor Is Leading Or Lagging?

To know whether power factor is leading or lagging, determine the direction of reactive power and the phase relationship between voltage and current. Inductive loads such as motors and transformers normally draw lagging current. Capacitors normally supply leading reactive current.…

LBAJI electrical equipment illustration for What Is An SF6 Circuit Breaker? Guide

What Is An SF6 Circuit Breaker? Guide

An SF6 circuit breaker is a high-voltage switching device that uses sulfur hexafluoride gas for insulation and arc interruption. The gas has high dielectric strength and can capture free electrons, allowing a compact interrupter to withstand recovery voltage after current…

LBAJI electrical equipment illustration for Air Switch Circuit Breaker

Air Switch Circuit Breaker: Guide

An air switch circuit breaker is an air-insulated switching and protection device that uses the surrounding air as its arc-insulation medium. The term is used for several low-voltage devices, including air circuit breakers, panel air switches and manually operated disconnects.…