SG(B) ENVIRONMENT-FRIENDLY DRY-TYPE TRANSFORMER

SG (B) 10 H-class insulated dry-type power transformer has strong thermal shock resistance, high overload capacity,flame retardancy,high fire resistance, low loss, small partial discharge, low noise, no harmful gas production, no environmental pollution, insensitivity to humidity and dust, small size, no cracking, and easy maintenance.

Catégorie :

Overview

SG (B) 10 H-class insulated dry-type power transformer has strong thermal shock resistance, high overload capacity,flame retardancy,high fire resistance, low loss, small partial discharge, low noise, no harmful gas production, no environmental pollution, insensitivity to humidity and dust, small size, no cracking, and easy maintenance. Therefore, it is most suitable for use in harsh environments with high fire prevention requirements, large load fluctuations, and dirty and humid conditions. Such as airports, power plants,metallurgical operations, hospitals, high-rise buildings, shopping centers, densely populated residential areas, as well as special environments such as petrochemicals, nuclear power plants, and nuclear submarines.

Iron core

The iron core is made of imported grain oriented high-quality high magnetic conductivity silicon steel sheets stacked together, The 45° fully inclined joint structure adopts an elastic fixing device between the winding and the iron core, which enables the transformer to have low no-load loss and noise.

The surface of the iron core is treated with special technology. which not only reduces the noise of the transformer but also prevents the iron core from rusting during operation.

The iron core is moderately camped by a pull screw, and the upper and lower clamping parts are connected by a pull plate and fixed to the base as a whole. The winding is fixed by elastic pads, and the buffering structure can reduce the vibration level and noise of the winding.

High and low voltage coils

The high and low voltage coils are made of Nomex insulation material and are repeatedly impregnated with solvent-free impregnating paint using VPI vacuum pressurization equipment, and then baked and cured at high temperatures multiple times. The high-voltage coil adopts  a continuous structure with high mechanical strength and good heart dissipation conditions,avoiding the disadvantages of high interlayer voltage,poor heat dissipation ability,easy thermal breakdown,and low mechanical strength of multi-layer cylindrical coils, thereby improving the reliability of product operation; The low-voltage coil adopts a foil or longitudinal airway high current spiral structure. The impregnated coil has excellent moisture resistance and can withstand impacts more effectively. It has no cracks or partial discharge, and is easy to dry, decompose, and recycle after its service life, protecting the environment.

Casing

If required by the user, our company can provide enclosures with protection levels of IP20 and IP23.

The meaning of the enclosure protection level IP20 is that solid foreign objects with a diameter of 12mm are not allowed to enter.

To ensure the circulation of cooling air, the bottom and top of the shell are made of mesh plates.

The meaning of the enclosure protection level IP23 is not only the same as IP20, but also to prevent water from entering within 60 degrees of the vertical line.

Overheat protection

To take protective measures against coil overheating. SG (B) 10 dry-type transformers of 315kVA and above are equipped with a temperature display protection device. This device uses temperature sensing elements embedded in the low-voltage winding as the signal source for the digital display instrument When the temperature inside the low-voltage winding changes, the temperature sensing digital display instrument displays a new temperature value and performs control and alarm functions based on this temperature value to protect the transformer.

Overload capacity

The SG (B) 10 dry-type power transformer adopts a new structure, new materials, and new processes, with good heat dissipation conditions, long thermal life, and extremely strong overload capacity. It can work safely and reliably for a long time under 120%overload. In the old 23 environment, there is no need for fan cooling and it can still operate at full load for a long time.

Secure

The SG (B) 10 new product s the highest safety performance dry-tpe transformer available today .All insulation materials are non combustible, self extinguishing. non-toxic, and contain less than 10% of flammable substances compared to epoxy cast products. They burn for a long time at a high temperature of 800℃ without producing toxic smoke,thus overcoming the defect of toxic gases produced during the combustion of epoxy cast transformers. The SG (B) 10 new product demonstrates superior performance in applications with high safety requirements, humid and hot conditions, and poor ventilation, such as power, subway, ship, chemical,and metallurgical industries.

Reliable

The special coil design, process, and materials of the SG (B) 10 new product provide excellent three proof performance (moisture-proof,mold proof, salt spray proof), better resistance to thermal shock, no cracking, and no partial discharge. The insulation system based on Nomex maintains excellent electrical and mechanical performance throughout the entire service life of the transformer, Nomex material is not prone to aging. resistant to shrinkage and compression, and has strong elasticity, which ensures that the coil of the transformer remains tightly structured even after years of use and can withstand the pressure of short circuits.

Protect the casing and output busbar

The Nomex insulation system dry-type transformer is capable of withstanding the invasion of moisture.

Adopting advanced VPI equipment and vacuum impregnation technology.

The high-quality impregnating paint recognized by U can operate continuously for a long time at temperatures of 180 ℃ and above.

Nomex paper is completely impregnated with impregnating varnish.

Smaller volume and lighter weight

The SG (B) 10 new product uses DuPont Nomex paper as the main insulation material and uses it as a hybrid insulation system at the hottest point of the transformer, reducing its size and weight compared to epoxy resin cast in transformers of the same capacity.

Environmental Protection

The SG (B) 10 new product can be decomposed and recycled after its service life, overcoming the defect of epoxy resin cast dry-type transformers that cannot be decomposed and pollute the environment due to the solidification and fusion of resin and glass fiber into a whole after its service life.

Model Meaning

Lead wire

The high-voltage output terminal is fixed on the upper part of the winding, and the tap is located in the middle of the winding. In the event of a power outage, the tap is changed through a connecting piece to adjust the output voltage.

The low-voltage outgoing terminal is a plate type conductive strip, which is reliably connected to the outgoing strip through bolts.

Normal condition

According to Article 1.2 of GB6450-1986 “Dry type Transformers”. When the maximum temperature of the environment is greater than 40 ℃ and the altitude is 1000m, it shall be corrected according to the relevant provisions of the national standard. Request the user to specify when placing an order.

Related standards&parameters

  • GB1094.11-2007 “Dry type Transformers”
  • GB/T10228-1997″Technical Parameters andRequirements for Dry type Power Transformers”
  • GB/T17211-1998 “Load Guide for Dry type Power Transformers”
  • JB/T10088-2004 “Sound Level of 6-220kV Power Transformers”
  • GB4208-1993 “Degrees of Protection Provided by Enclosures (IP Code)”

Appearance and installation dimensions

Technical parameters

10KV SG (B) 11H environmentally friendly dry-type transformer

Rated
capacity
(KVA)
Voltage combination
and tap range (kV)
connection
symbol
No
load
loss
(kW)
Load loss at different insulation
system temperatures (Kw)
No
load
current
(%)
Short
circuit
impedance
(%)
Weight
(kg)
Dimensions(mm)
(L in length,B in
width,and H in
height)
Installation
size
With shell size
(L×W×H)
High
Pressure
(kV)
High voltage
division Range
of acceptance
(%)
Low
Pressure
(kV)
130℃(B)
(100℃)
155℃(B)
(120℃)
80℃(B)
(145℃)
100 6
6.3
6.6
10
10.5
11
±2.5
±5
0.4 Dyn11
Yyn0
0.36 1.69 4 590 850×600×830 400/450 1250×1000×2200
125 0.42 1.98 650 870×650×890 550/550 1300×1000×2200
160 ±2×2.5
±5
0.48 2.28 800 900×710×930 550/550 1300×1100×2200
200 0.56 2.71 880 940×750×980 550/660 1350×1100×2200
250 0.65 2.96 1050 990×770×1030 660/660 1400×1150×2200
315 0.79 3.73 1260 1020×790×1080 660/660 1450×1150×2200
400 0.88 4.28 1570 1060×880×1180 660/820 1450×1200×2200
500 1.04 5.23 1780 1090×900×1220 660/820 1500×1200×2200
630 1.17 6.4 6 1860 1200×920×1150 820/820 1600×1200×2200
800 1.37 7.46 2180 1260×920×1200 820/820 1650×1200×2200
1000 1.59 8.76 2590 1320×950×1250 820/820 1750×1300×2200
1250 1.88 10.3 2980 1350×980×1320 820/820 1750×1350×2200
1600 2.2 12.5 3580 1400×1120×1400 1070/1070 1800×1400×2200
2000 2.75 15.5 4070 1440×1120×1520 1070/1070 1850×1450×2200
2500 3.24 18.4 4820 1500×1120×1640 1070/1070 1900×1500×2200

10KV SG (B) 13H environmentally friendly dry-type transformer

Rated
capacity
(KVA)
Voltage combination
and tap range (kV)
connection
symbol
No
load
loss
(kW)
Load loss at different insulation
system temperatures (Kw)
No
load
current
(%)
Short
circuit
impedance
(%)
Weight
(kg)
Dimensions(mm)
(L in length,B in
width,and H in
height)
Installation
size
With shell size
(L×W×H)
High
Pressure
(kV)
High voltage
division Range
of acceptance
(%)
Low
Pressure
(kV)
130℃(B)
(100℃)
155℃(B)
(120℃)
80℃(B)
(145℃)
100 6
6.3
6.6
10
10.5
11
±2.5
±5
0.4 Dyn11
Yyn0
0.29 1.69 1.5 4 590 850×600×830 400/450 1250×1000×2200
125 0.34 1.98 1.3 650 870×650×890 550/550 1300×1000×2200
160 ±2×2.5
±5
0.38 2.28 13 800 900×710×930 550/550 1300×1100×2200
200 0.45 2.71 1.1 880 940×750×980 550/660 1350×1100×2200
250 0.52 2.96 11 1050 990×770×1030 660/660 1400×1150×2200
315 0.64 3.73 1 1260 1020×790×1080 660/660 1450×1150×2200
400 0.7 4.28 1 1570 1060×880×1180 660/820 1450×1200×2200
500 0.83 5.23 1 1780 1090×900×1220 660/820 1500×1200×2200
630 0.94 6.4 0.85 6 1860 1200×920×1150 820/820 1600×1200×2200
800 1.1 7.46 0.85 2180 1260×920×1200 820/820 1650×1200×2200
1000 1.27 8.76 0.85 2590 1320×950×1250 820/820 1750×1300×2200
1250 1.5 10.3 0.85 2980 1350×980×1320 820/820 1750×1350×2200
1600 1.76 12.5 0.85 3580 1400×1120×1400 1070/1070 1800×1400×2200
2000 2.2 15.5 0.7 4070 1440×1120×1520 1070/1070 1850×1450×2200
2500 2.6 18.4 0.7 4820 1500×1120×1640 1070/1070 1900×1500×2200