Tableau basse tension GGD

The GGD-type low-voltage AC distribution switchgear is designed for 50 Hz AC distribution systems with a rated operational voltage of 380 V and a rated current of up to 3,150 A. It is widely used by electrical power users such as power plants, substations, and industrial and mining enterprises for the distribution and control of electrical energy for power, lighting, and other distribution equipment.

Overview

The GGD-type low-voltage AC distribution switchgear is a new-generation low-voltage distribution switchgear assembly developed in accordance with the requirements of power users and electrical design organizations, with a focus on safety, economy, practicality, and reliability. The product features high short-circuit breaking capacity, excellent dynamic and thermal stability, flexible circuit configurations, convenient assembly, a comprehensive product range, a novel structure, and a high degree of protection. It serves as an upgraded product for low-voltage switchgear and controlgear assemblies. The GGD-type low-voltage AC distribution switchgear is designed and manufactured in accordance with IEC 61439 and the applicable requirements of the GB/T 7251 series.

Service Conditions

  1. Ambient air temperature: −5 °C to +40 °C; the 24-hour average temperature shall not exceed +35 °C.
  2. Altitude: The installation site shall not exceed 2,000 m above sea level. The equipment is intended for indoor installation and operation.
  3. Relative humidity: The relative humidity shall not exceed 50% at a maximum ambient temperature of +40 °C. Higher relative humidity is permitted at lower temperatures, for example, up to 90% at +20 °C, taking into account the possibility of occasional condensation caused by temperature variations.
  4. Installation inclination: The equipment shall be installed with an inclination of no more than 5° from the vertical plane.
  5. Installation site: The equipment shall be installed in a location free from severe vibration, shock, and corrosive gases or vapors that may adversely affect electrical components.
  6. Any special requirements shall be agreed upon with the manufacturer.

Avis

Il n’y a pas encore d’avis.

Soyez le premier à laisser votre avis sur “GGD Low-Voltage Switchgear”

Votre adresse e-mail ne sera pas publiée. Les champs obligatoires sont indiqués avec *

Foire aux questions

What types of switchgear does LBAJI provide?

LBAJI provides:

Appareillage de commutation moyenne tension

  • Appareillage blindé à enveloppe métallique KYN28A
  • Unité principale en anneau
  • Appareillage de commutation de la série XGN

Appareillage à basse tension :

  • Appareillage de commutation GGD
  • Appareillage de commutation GCS
  • Appareillage MNS
  • Armoires de commande MCC
  • Tableaux de distribution
What voltage levels are available for your switchgear?

Our switchgear solutions cover:

Moyenne tension :

  • 6kV
  • 10kV
  • 11kV
  • 12kV
  • 24kV
  • 35kV

Basse tension :

  • 400V
  • 415V
  • 480V
  • Customized voltage levels
Can you supply complete switchgear systems?

Yes.

LBAJI provides complete solutions including:

  • Appareillage d'arrivée
  • Départs
  • Panneaux de protection
  • Tableaux de comptage
  • Panneaux de commande
  • Systèmes de communication SCADA

Nous pouvons fournir un ensemble complet basé sur votre conception de distribution d'électricité.