GGD Low-Voltage Switchgear

The GGD-type low-voltage AC distribution switchgear is designed for 50 Hz AC distribution systems with a rated operational voltage of 380 V and a rated current of up to 3,150 A. It is widely used by electrical power users such as power plants, substations, and industrial and mining enterprises for the distribution and control of electrical energy for power, lighting, and other distribution equipment.

GGD low-voltage switchgear is an indoor, fixed-configuration AC distribution cabinet for low-voltage power distribution and control applications. This page describes the published installation conditions and the information required to specify a project cabinet. The final electrical ratings, circuit arrangement, protection devices and dimensions must be confirmed against the approved drawings and manufacturer data sheet.

Where a GGD Cabinet Fits

Published GGD series-level values

Published parameter Series-level information Confirm for the offered cabinet
AC frequency 50 Hz Confirm compatibility with the project supply and exact equipment configuration.
Rated working voltage 380 V Confirm system voltage, insulation coordination and the voltage assigned to each circuit.
Rated working current Up to 3,150 A across the published series description Confirm the selected incomer, busbars, feeder ratings and temperature-rise verification for the specific lineup.
Published series-level information only; it is not a rating guarantee for every cabinet arrangement.

These values do not establish short-circuit withstand, breaker interrupting capacity, protection settings, enclosure rating, circuit count or dimensions. Require the supplier to state those model- and project-specific values in the approved technical schedule.

Use a GGD assembly when the project calls for a low-voltage distribution cabinet with a defined incoming supply, outgoing circuits and protection arrangement. The selection depends on the actual one-line diagram, connected loads, available short-circuit current and service access. A model name alone cannot establish the busbar rating, fault withstand, enclosure degree or number of feeders. Those values belong in the project-specific technical schedule.

The existing product description states that this GGD series is designed and manufactured in accordance with IEC 61439 and the applicable GB/T 7251 requirements. Ask for the applicable design-verification and routine-verification documents for the offered configuration. Standard references do not substitute for reviewing the exact assembly and installation.

GGD Switchgear Specification Checklist

Specification field Information to provide or confirm Why it matters
System and incoming supply Nominal voltage, phase, frequency, earthing arrangement and incoming cable or busduct details Determines component and connection requirements
Current and fault duty Calculated load, required busbar current, available short-circuit current and protection study Supports thermal and short-circuit verification
Outgoing circuits Feeder count, ratings, protective-device types, metering and spare ways Defines the actual panel arrangement
Installation Indoor room conditions, cable-entry direction, access clearances and space available Checks the cabinet against the physical site
Documentation Single-line drawing, layout, component list, verification records and operation manual Allows review before manufacture and acceptance
Project data to confirm before a GGD low-voltage switchgear quotation. This checklist does not assert an unverified rating for the cabinet.

Configuration and Acceptance

For a new build, submit the one-line diagram and load schedule before the cabinet arrangement is finalized. Identify which feeders are essential, which require metering and which may expand later. For a replacement, add photos of the existing nameplate, connection points and installation space. Confirm the direction of cable entry and the path needed to move the equipment into place.

Before acceptance, compare the delivered cabinet against the approved drawing and agreed component list. Request the applicable verification records, routine test results, wiring drawings and final nameplate information. Confirm labels, access, clearances and protection settings with the project engineer. Electrical work and commissioning must follow local rules and qualified-person procedures.

Request a Project-Specific GGD Quotation

For a structured inquiry, download the GGD project specification and RFQ worksheet (PDF). It collects the buyer’s requirements and supplier confirmations; it is not a certified product datasheet.

Send the rated system information, single-line diagram, feeder schedule, short-circuit study, installation conditions, quantity and delivery location through the contact page. If the design is still being compared, review our switchgear versus switchboard guide and electrical control panel guide to separate distribution and control requirements.

Service Conditions

  1. Ambient air temperature: −5 °C to +40 °C; the 24-hour average temperature shall not exceed +35 °C.
  2. Altitude: The installation site shall not exceed 2,000 m above sea level. The equipment is intended for indoor installation and operation.
  3. Relative humidity: The relative humidity shall not exceed 50% at a maximum ambient temperature of +40 °C. Higher relative humidity is permitted at lower temperatures, for example, up to 90% at +20 °C, taking into account the possibility of occasional condensation caused by temperature variations.
  4. Installation inclination: The equipment shall be installed with an inclination of no more than 5° from the vertical plane.
  5. Installation site: The equipment shall be installed in a location free from severe vibration, shock, and corrosive gases or vapors that may adversely affect electrical components.
  6. Any special requirements shall be agreed upon with the manufacturer.

Reviews

There are no reviews yet.

Be the first to review “GGD Low-Voltage Switchgear”

Your email address will not be published. Required fields are marked *

Frequently Asked Questions

What types of switchgear does LBAJI provide?

LBAJI provides:

Medium Voltage Switchgear:

  • KYN28A Metal Clad Switchgear
  • RMU Ring Main Unit
  • XGN Series Switchgear

Low Voltage Switchgear:

  • GGD Switchgear
  • GCS Switchgear
  • MNS Switchgear
  • MCC Control Cabinets
  • Distribution Panels
What voltage levels are available for your switchgear?

Our switchgear solutions cover:

Medium Voltage:

  • 6kV
  • 10kV
  • 11kV
  • 12kV
  • 24kV
  • 35kV

Low Voltage:

  • 400V
  • 415V
  • 480V
  • Customized voltage levels
Can you supply complete switchgear systems?

Yes.

LBAJI provides complete solutions including:

  • Incoming switchgear
  • Outgoing feeders
  • Protection panels
  • Metering panels
  • Control panels
  • SCADA communication systems

We can provide a complete package based on your power distribution design.