Overview
The core design philosophy prioritizes product reliability and enhanced performance. During development, we recalibrated loss parameters and structural configurations in accordance with practical operating conditions of modern power equipment, so that calculated loss figures closely match measured test values.
The product adopts optimized structural design with a well-balanced copper-to-iron material ratio, which minimizes raw material costs while delivering a more compact and rational mechanical structure.
Paramètres techniques
| Classé Capacité (kVA) |
Voltage Combination And Tap Range |
Vector Group |
Non Load Perte(W) |
Load Perte(W) |
Non Load Actuel (%) |
Short Circuit Impédance (%) |
Overall Size(mm) | Gauge | Poids (kg) |
||||
| Haut Tension (kV) |
Tap Range ±% |
Faible Tension (kV) |
Length (L) |
Width (VV) |
Height (H) |
Horizx Vert ax b |
|||||||
| 30 | 6 6.3 10 10.5 11 |
±5% ±2×2.5% |
0.4 | Dyn11 Yyno |
100 | 630/600 | 1.5 | 4.0% | 690 | 510 | 920 | 400×400 | 275 |
| 50 | 130 | 910/870 | 1.3 | 730 | 510 | 960 | 400×450 | 340 | |||||
| 63 | 150 | 1090/1040 | 1.2 | 750 | 550 | 1000 | 400×450 | 385 | |||||
| 80 | 180 | 1310/1250 | 1.2 | 790 | 620 | 1020 | 400×450 | 450 | |||||
| 100 | 200 | 1580/1500 | 1.1 | 790 | 700 | 1040 | 550×550 | 520 | |||||
| 125 | 240 | 1890/1800 | 1.1 | 840 | 800 | 1070 | 550×550 | 625 | |||||
| 160 | 280 | 2310/2200 | 1.0 | 1070 | 670 | 1130 | 550×550 | 695 | |||||
| 200 | 340 | 2730/2600 | 1.0 | 1140 | 750 | 1140 | 550×550 | 795 | |||||
| 250 | 400 | 3200/3050 | 0.9 | 1200 | 800 | 1190 | 550×550 | 955 | |||||
| 315 | 480 | 3830/3650 | 0.9 | 1300 | 860 | 1210 | 550×550 | 1085 | |||||
| 400 | 570 | 4520/4300 | 0.8 | 1380 | 900 | 1240 | 660×660 | 1290 | |||||
| 500 | 680 | 5410/5100 | 0.8 | 1450 | 950 | 1300 | 660×660 | 1590 | |||||
| 630 | 810 | 6200 | 0.6 | 4.5% | 1500 | 970 | 1360 | 660×660 | 1850 | ||||
| 800 | 980 | 7500 | 0.6 | 1660 | 1140 | 1400 | 660×660 | 2210 | |||||
| 1000 | 1150 | 10300 | 0.6 | 1690 | 1190 | 1530 | 660×660 | 2570 | |||||
| 1250 | 1360 | 12000 | 0.5 | 1760 | 1230 | 1600 | 820×820 | 3115 | |||||
| 1600 | 1640 | 14500 | 0.5 | 1800 | 1250 | 1660 | 820×820 | 3520 | |||||
| 2000 | 1940 | 18300 | 0.4 | 5.0% | 2070 | 1270 | 1880 | 820×820 | 4375 | ||||
| 2500 | 2290 | 21200 | 0.4 | 2180 | 1320 | 1970 | 820×820 | 4950 | |||||
Note 1: For transformers rated 500 kVA and below, load loss figures above the slash apply to Dyn11 or Yzn11 vector groups, while those below the slash correspond to the Yyn0 vector group.
Note 2: When the transformer’s annual average load factor ranges from 35% to 40%, the loss values listed in the table deliver maximum operational efficiency.